R603 UPDATE-25 2/10/94 <br /> pounds per day destruction was increased to nearly 70 pounds per <br /> 40 day on August 23, 1993 , just prior to turning the system off for <br /> repair of the compressor and changing the pilot/burner assembly. <br /> Presently the system is destroying an estimated 31 pounds per day <br /> of gasoline range hydrocarbons, see Table 2 . <br /> CONDENSATE REMOVAL BY LTT <br /> Condensation from vapor extraction is collected in moisture drop <br /> out tanks constructed of 121" PVC pipe, before the manifold, to <br /> prevent moisture build up on the vacuum pump filter. All fluids <br /> removed from the condensation traps are placed in the 1000 gallon <br /> "ConVault" As of November 29, 1993 LTT had removed an estimated <br /> 5047 gallons of condensate/water and 26 . 25 gallons of product <br /> from the condensate traps. Total fluids removed as of December <br /> 15, 1993 • 5209 gallons of water/condensate and 48 75 gallons of <br /> product (162 previously recovered condensate water and 22 . 5 <br /> gallons of product) <br /> 4 . 0 SUMMARY <br /> There has been no evidence of floating product or product sheen <br /> on the ground water in MW1 since April 14 , 1992 and MW3 and MW10 <br /> since November 11, 1992 Only occasional product sheen is found <br /> with the condensate recovered from the vapor extraction moisture <br /> dropouts and manifold Vapor recovery has reduced the <br /> hydrocarbons in ground water significantly since the May 25, 1990 <br /> sampling, see Table 1 Using benzene as an indicator, monitoring <br /> wells MW1, MW4 , MWS, MW6 , MW7 and MW9 have been reduced to below <br /> detection limits while the wells being utilized for vapor <br /> extraction (MW3 , and MW10) have been reduced by better than 9996 <br /> MW2, which is also used for vapor extraction has been reduced 97%- <br /> and MW8 has been reduced by approximately 74%- Of the newly <br /> installed wells MW11 and MW12 , MW12 has not shown any significant <br /> change in benzene concentrations until this most recent sampling, <br /> where all of the gasoline range hydrocarbons/BTEX have increased <br /> MW11 has always tested below detection limits <br /> On December 22 , 1993 , a sample of the water being treated by air <br /> stripping inside the "ConVault" was obtained for certified <br /> laboratory analysis This was accomplished to prove the <br /> suitability for dumping the approximately 800 gallons of this <br /> cleaned water to the City of Stockton' s sanitary sewer, see <br /> Appendix B and Table 4 . <br /> As of February 2 , 1994 an estimated 11628 gallons of gasoline <br /> range hydrocarbons have been removed from the soil and ground <br /> water beneath this site Previously removed floating product <br /> (40 . 25 gallons) , condensation from vapor extraction (48 . 75 <br /> gallons) , pro3ected petroleum hydrocarbon vapor extraction- <br /> destruction (72119 pounds/6 25 = 11539 gallons) No chlorinated <br /> solvents were detected in chromatogram comparisons, "i .e . " 1, 2 , - <br /> Dichloroethane (DCE) retention time 2 079 minutes, <br /> Trichloroethylene (TCE) retention time 3 . 023 minutes and <br /> PAGE 3 <br />