Laserfiche WebLink
WOPERATION DATA TABLE 3 <br /> R REGAL STATION 603 6425 PACIFIC AVENUE STOCKTON, CALIFORNIA <br /> DATE TIME 'TOTAL HOURS RUN OFF V RUN NAT GAS TOTAL NAT GAS WELL TOTAL % INFLUENT EFFLUENT Ir DEST TEMP <br /> HOURS BETWEEN HOURS HOURS TIME CUBIC HOURS USEAGE FLOW FLOW AIR VOC S VOC•S DESTRUCT <br /> AVAILABLE CHECKS FEET RUN CFM CFM CFM DILUTE PPM VAPOR PPM VAPOR F <br /> 09/29/93 10 5 9760 5 RESTART UNIT 0 2689520 0 ERR 92 5 159 7 42 1 697 50 NS ERR 1600 <br /> 09/29/93 17 5 9767 5 7 7 0 100 0 2691050 7 3 6 104 2 104 2 0 0 1472 50 22 50 98 4 1815 <br /> 10/06/93 16 9934 166 5 123 5 43 74 2 2714250 130 5 3 1 152 152 0 0 747 50 na ERR 1433 <br /> 10/14/93 11 10121 187 29 75 157 25 15 9 2724470 160 3 5 7 152 152 0 0 295 00 no ERR 1433 <br /> 10/19/93 20 10240 119 8 111 6 7 2724470 168 3 0 0 152 152 0 0 NS no ERR 1433 <br /> 11/04/93 13 8 10627 75 387 75 55 75 332 14 4 2732750 224 2 5 191 191 0 0 NS ns ERR 1433 <br /> REPLACE BURNER/PILOT ASSEMBLY ON NOVEMBER 4-5 1993 <br /> 11/05/93 17 5 10655 5 27 75 1 55 26 2 5 6 2733680 1 55 10 0 188 7 180 7 0 0 527 50 17 50 96 5 1433 <br /> 11/17/93 17 5 10943 5 288 288 0 100 0 289 6 123 123 0 0 1132 50 no ERR 1433 <br /> 11/30/93 17 11255 311 5 311 5 0 100 0 2870950 601 1 3 8 169 169 0 0 295 00 37 50 87 0 1433 <br /> 12/07/93 18 11424 169 169 0 100 0 2912150 770 1 4 1 137 5 137 5 0 0 467 50 no ERR 1433 <br /> 12/18/93 12 11682 258 108 150 41 9 2946200 878 1 5 3 137 5 137 5 0 0 NS NS ERR 1433 <br /> NAT GAS NATURAL GAS From August 26 to September 22, 1992 the unit operated 343 5/653 hours = 52 61r <br /> CFM CUBIC FEET PER MINUTE From September 18 to October 18, 1992 the unit operated 624/720 hours = 86 6} <br /> VOC'S VOLATILE ORGANIC COMPOUNDS, GASOLINE RANGE From October 18, to November 18 1992 the unit operated 547 5/744 hours 73 6% <br /> t PERCENT PPM PARTS PER MILLION From November 18, to December 18, 1992 the unit operated 516 5/720 hours 71 71 <br /> From Dec 18 1992 to Jan 18 1993, the unit operated 383 75/737 75 hours - 52t <br /> From Jan 18 to Feb 18, 1993 the unit operated 746/746 hours . 100% <br /> From Feb 18, to Mar 18 1993, the unit operated 499 5/671 5 hours = 74 4V <br /> From Mar 18 to April 18 1993, the unit operated 520/743 hours - 71% <br /> From April IS to May 10, 1993 the unit operated 694/722 hours - 96% <br /> From May 18 to June 18, 1993 the unit operated 743/743 hours - 1001 <br /> From June 18 July 19, 1993 the unit operated 749/749 hours = 106t <br /> From July 19 to August 18, 1993 the unit operated 236/716 hours - 33% <br /> From Aug 18 to Sept 18, 1993 shut down due to high noise level(Kevin Morisset) <br /> operated 120 75/744 hrs = 16% <br /> Restarted 9/29/93 (credit 1 day-Milt notified WEGE on 9/28/93 unit was ready to <br /> From Sept 19 to Oct 16, 1993 unit operated 168 25+24/720 hrs = 274 <br /> From Oct 18, to Nov 18, 1993 unit operated 369 5/744 hrs - 49 7% <br /> From Nov 18, to Dec 18, 1993 unit operated 594/744 hrs a 801 <br /> 24 <br />