Laserfiche WebLink
Plume and will enhance biodegradation by removing CO2 and <br /> enhancing oxygen transfer while limiting hydrocarbon removal to <br /> less than 0 1 pound per week Mr Mark Schonhoff of San Joaquin <br /> Valley Unified Air Pollution Control District, evaluating this <br /> source test as it pertains to air quality conditions in the <br /> Stockton area and has allowed Wickland to perform the weekly two <br /> hour venting of this well <br /> The weekly venting of MW8 commenced on Janaury 25, 1995 and each <br /> lasts a duration of two hours The average flow rate calculated <br /> during during these venting events is 64 cfm with an average <br /> vapor stream containing 0 111 mg/L as gasoline and 2 116 carbon <br /> dioxide, see Table 3 <br /> The above results show that the weekly two hour venting of MW8 , <br /> is removing excess carbon dioxide and allowing oxygen transfer to <br /> occur A calculated 2 39 pounds of gasoline range hydrocarbons <br /> has been removed from MW8 as of March 12 , 1996, see Table 3 and <br /> Appendix B - Field Notes . <br /> MW8 VENTING PROCEDURES <br /> WEGE is using LTT vacuum trucks to pull an estimated 7 - 10 feet <br /> of water vacuum on MW8 , for 2 hours weekly and exhaust directly <br /> to atmosphere This vacuum generates a flow rate of <br /> approximately 64 cfm <br /> COLLECTING SAMPLES <br /> The sample is obtained from a sample port located, prior to the <br /> vacuum pump from a sample port on the flow meter orifice Sterile <br /> poly tubing was used to attach a one liter tedlar bag, fitted <br /> with a special septum "valve" and tubing bib, to the sample port <br /> The sample port is on the vaccum side of the pump and therefore a <br /> vacuum greater than the well vacuum must be exerted on the <br /> outside of the tedlar bag to " fill" the bag with the vapor <br /> sample A special vacuum box, in which the tedlar bag is sealed <br /> inside, is used to exert a high vacuum to the exterior of the <br /> bag, thereby pulling a sample into the bag Once the tedlar bag <br /> is fill,, a �� ,._ , <br /> cd, iICS va-1 is c" oseu ail ' mucked and zhe appropriate <br /> label is placed on the bag <br /> The label shows the date, time, sample ID# and analyses to be run <br /> and the sampler' s initials The tedlar bag samples are then <br /> placed within a cooler, and are hand delivered to WEnF' s <br /> laboratory that same day <br /> The vapor sample is then infected into an FID (Flame Ionizing <br /> Detector) chromatograph and the resulting chromatogram compared <br /> to standard chromatograms of known TPHg (Total Petroleum <br /> Hydrocarbons, gasoline) and BTEX (benzene, toluene, ethylbenzene, <br /> and xylenes) concentrations Selected samples are also analyzed <br /> by second column chromatograph comparison A Photovac 1OS50 <br /> photo-ionizing gas chromatograph was used to evaluate BTEX, TCE, <br /> PCE, and DCE <br /> PAGE 3 RG03 UPDATE-43 3/25/96 <br />