See table 1 for the results of REMOX operation and table 2 for <br /> results influent/effluent monitoring of the system. <br /> CONCLUSIONS <br /> The VOC emissions during current REMOX operations for the period <br /> 10/10/91 to 03/18/92, have not exceeded the 52 lb/day limit. <br /> Natural Gas usage, a total of 341640cf Methane has been used <br /> during 2611 hours of operation, averaging 130 . 8 cfh, 2 . 2 cfm, or <br /> 3, 170 cf per operational day, which is below the permit limit of <br /> 17, 290 . <br /> A total of 16156 pounds of gasoline have been destroyed during the <br /> course operation of the vapor recovery system. <br /> ackE . N r R utler <br /> Reg. Geologist # 3037 Geologist <br /> CC. <br /> Tom Peterson <br /> . San Joaquin Valley <br /> Unified Air Pollution Control District <br /> P.O. Box 2009 <br /> Stockton, California 95201 <br /> Mary F. Meays <br /> Public Health Services <br /> P.O. Box 2009 <br /> Stockton, California 95201 <br /> 6 <br />