Laserfiche WebLink
MONITWING SYSTEM CERTF CATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION /TEST DATE: May 19, 2008 <br />Al. FACILITY <br />A2. OWNER <br />Name Waterloo Shell <br />Name Bill and Cathie Norby <br />Address 4315 E. Waterloo Road, Stockton, CA 95215 <br />Address 2303 Woodlake Circle, Lodi, CA 95242 <br />Phone# 209-369-2252 <br />Phone# 209-931-3674 <br />Contact Bill and Cathie Norby <br />Contact Bill and Cathie Norby <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 600 E. Main Street , Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified May 13, 2008 <br />Lic # 617238 A, B, Haz <br />Inspector Garrett Backus <br />Contact Richard Walton <br />Phone# 209-468-3439 <br />Phone# 916-825-3203 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check <br />the appropriate boxes to indicate equipment inspected/serviced) <br />131: <br />TANKS <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Gasoline - 91 <br />■ In -Tank Gauging Probe Model: 0847390-109 <br />■ In -Tank Gauging Probe Model: 0847390-109 <br />■ Annular Space or Vault Sensor Model: 0794380-303 <br />■ Annular Space or Vault Sensor Model: 0794380-303 <br />■ Piping Sump I Trench Sensor(s) Model: 0794380-208 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380-208 <br />■ Fill Sump Sensor(s) Model: 0794380-208 <br />■ Fill Sump Sensor(s) Model: 0794380-208 <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />■ Electronic Line Leak Detector Model: 0848480-001 <br />■ Electronic Line Leak Detector Model: 0848480-001 <br />■ Tank Overfill I High -Level Sensor Model: OPW61SO <br />■ Tank Overfill / High -Level Sensor Model: OPW61SO <br />■ Other (specify equipment in Section E) Model: <br />■ Other (specify equipment in Section E) Model: <br />Tank #3 (Product): <br />Tank #4 (Product): <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />B2: DISPENSERS/UDC's <br />Dispenser # : 1-2 Dispenser # : 3-4 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves ■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 5-6 Dispenser # : 7-8 <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br />■ Shear Valves ■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : Vent box Dispenser # : <br />■ Dispenser Containment Sensor(s) Model: 0794380-208 ❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspectedlserviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />WALTON <br />Signature: ENGINEERING, INC. <br />Technician / Cert #: Bruce N. Stewart I A31131 5249892 -UT Date: May 19, 2008 <br />zuuo wanon tngineenng, mc. <br />