Laserfiche WebLink
SYWEM SET-UP REPORT <br />LEHF: TEST METHOD <br />TEST ON DATE : ALL TAN(. <br />FEB a. 2005 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL:'HR <br />DURATION : 2 HOURS <br />TST EARL`! STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />PRESSURE LINE LEAF: SETUP <br />Q 1:87 <br />TYP:2.0 3.01N FIBERGLASS <br />2.0IN DIA LEN: 125 FEET <br />3.0IN DIA LEN: 0 FEET <br />SHUTDOWN RATE: 3.0 GPH <br />LOW PRESSURE SHUTOFF:NO <br />LOW PRESSURE : 0 PSI <br />T 1:87 <br />DISPENSE MOUE: <br />STANDARD <br />SENSOR: NON -VENTED <br />PRESSURE OFFSET: O.OPSI <br />f`rF:"'-0.,3.01N FIBERGLASS <br />2.01N DIA LEN: 165 FEET <br />3.01N DIA LEN: 0 FEET <br />SHUTDOWN RATE: 3.0 13PH <br />LOW PRESSURE SHUTOFF:NQ <br />LOW PRESSURE 0 PSI <br />T -:91 <br />DISPENSE MODE : <br />STANDARD <br />SENSOR: VENTED <br />PRESSURE OFFSET: 0.0PSI <br />LIQUID SENSOR SETUP <br />L 1:87 FILL <br />TRI-STATE (SINGLE FLOAT) <br />'ATEi,ORY : PIPING SUMP <br />L 2:91 FILL <br />TP. I -L THT'E (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L '3:87 STP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SU -IF <br />L 4:91 STP <br />TRI-STATE tSINGLE FLOAT) <br />CATEGORY : STP SUMP <br />© 2006 Walton Engineering, Inc. <br />L 5:87 ANNULAR <br />DUAL. PO I NT HYDROS PAT 11:' <br />CATEGORY : ANNULAR SPA+'E <br />L 6:91 ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 7:DISP 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 8:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />,'ATEGOR`,` ' DISPENSER PAN <br />L 9:DI*sP 5-6 <br />TRI-STHTE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L10:DISP 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />LII:DISP 1-2 ANN <br />TRI-STATE (SINGLE FLOAT <br />ATEGOP.Y : ANNULAR SPACE <br />L12:DISP 3-4 ANN <br />TRI - ST'ATE (S 1 (*,LE FLOAT) <br />ATEGOR'r ANNULAR SPACE <br />L13:DISP 5-6 ANN <br />TRI-ST'ATE (SINGLE FLOAT) <br />"ATE('OR'I,* : ANNULAR SPACE <br />L•14:1)ISF 7-8 ANN <br />TR I -STAT L: (S I NG LE FLOAT) <br />CATEGORY : ANNULAR SPP—,*E <br />L15:87 STP HNN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L16:91 STP ANN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 17 : VENT BO.,,: <br />TRI-STATE (SINGLE FLOfIT) <br />CATEGORY : PIPING SOMP <br />L1S:VENT ANN <br />TRI-STATE (SINGLE FLOAT) <br />(;ATEGOA.`f : ANNULAR SPACE <br />(Page 2) <br />L19:87 FILL ANN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L20:91 FILL ANN <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />PLLD LINE DISABLE SETUF <br />Q 1:87 <br />LIQUID SENSOR ALMS <br />L 3:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALHRM <br />LIO:FUEL ALARM <br />L 3:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />L 10 : SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />L 9:SHORT ALARM <br />LIO:SHORT ALARM <br />PRESSURE LINE LEAK <br />Q I:PLL.D OPEN ALARM <br />SMARTSENSOR ALARMS <br />s (:COMMUNICATION ALARM <br />3 I:FUEL ALARM <br />s I:HIGH LIQUID ALARM <br />Q 2:91 <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALARM <br />L10:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />LIO:SENSOR OUT HLARM <br />L 4:SHOP.T ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />L 9 : SHOF.T ALARM <br />L10:SHORT ALARM <br />PRESSURE LINE LEAK <br />0 2:PLLD OPEN ALARM <br />SMARTSENSOR ALARMS <br />s 3:00MMUNI,ATION ALARM <br />s 3:FUEL ALARM <br />s 3:H1GH LIQUID ALARM <br />