My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0006523
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2900 - Site Mitigation Program
>
PR0519189
>
ARCHIVED REPORTS XR0006523
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 3:52:58 PM
Creation date
8/21/2019 3:04:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006523
RECORD_ID
PR0519189
PE
2950
FACILITY_ID
FA0014347
FACILITY_NAME
CURRENTLY VACANT
STREET_NUMBER
6425
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09741031
CURRENT_STATUS
02
SITE_LOCATION
6425 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ON SITE ANALYSIS <br /> Besides bag samples collected for the WEGE laboratory some samples <br /> may be run on site using a Photovac 10550 PID chromatograph. <br /> The influent and effluent samples are collected from the same ports <br /> as the bag samples but 60 cc syringes are used to collect the sample <br /> and 0 . 5 cc of the vapor sample are then injected directly into the <br /> PID chromatograph. The resulting chromatogram is then compared to a <br /> standard run on the same chromatograph prior to the sample run. <br /> During the initial month of operation, three effluent samples were <br /> obtained during the day and analyzed using the lOS50 chromatograph. <br /> The highest value is used to calculate the VOC poundage per day <br /> produced. Presently, an influent and an effluent sample are <br /> obtained upon arrival to the site. Adjustments are then made to the <br /> vapor extraction system: removal of liquids from the condensation <br /> traps, closing the air dilute valve to maximize vapor removal, <br /> without causing the REMOX Unit to shut down due to high temperature <br /> shut off (greater than 15500F) ; and closing the pump bypass to <br /> create maximum flow and vacuum from the wells . Once, these <br /> adjustments have been completed and the system has stabilized, <br /> influent and effluent samples are again obtained, along with samples <br /> from the individual extraction orifices (wells) The site is then <br /> secured until the next visit <br /> FLOW RATES <br /> Flow rates are measured at the site by use of orifice plates . A one <br /> inch orifice is placed in line for each well and a three inch <br /> orifice is used to measure the total flow An orifice plate <br /> restricts the flow of air across it This restriction causes a <br /> pressure drop across the orifice By measuring the resulting <br /> pressure change across the orifice it is possible to calculate the <br /> air flow rate . The flow rate is calculated by the pressure drop <br /> (millimeters (mm) water) across a square edge orifice plate <br /> Ve = CK sgr (P) Q = AVe <br /> Where : <br /> �- ' Ve= velocity in feet per minute (fpm) <br /> C = Orifice Coefficient = 0 65 (for orifice used) <br /> K = Constant = 794 6 mm water <br /> P = Pressure differential across the orifice <br /> Q = Flow rate in cubic feet per minute (CFM) <br /> A = Area orifice in square feet . 1" = 0 . 00545 ft2 <br /> Q = A X 0 . 65 X 794 6 X sgr(P) 3 " = 0 04909 ft2 <br /> page 3 of R603 , 10/21/93 <br />
The URL can be used to link to this page
Your browser does not support the video tag.