i <br /> RESULTS <br /> See Table 1 for results influent/effluent monitoring of the system <br /> and Table 2 for the results of REMOX operation <br /> CONCLUSIONS <br /> The VOC emissions during current REMOX operations for the period <br /> 10/10/91 to 07/19/93 , have not exceeded the 52 lb/day limit . No DCE, <br /> TCE or PCE has been detected in the samples . <br /> The average Natural Gas usage to 7/20/92 was 2 2 cfm, or 3168 cf per <br /> operational day, following the exchange of the unit on 8/18/92 the <br /> average Natural Gas usage has been 5 4 cfm or 7785 cfd, which is <br /> below the permit limit of 17, 280 cfd <br /> A total of 70155 pounds of gasoline have been destroyed during <br /> operation of the vapor recovery system. <br /> The system is currently destroying, as of 07/19/93 , 30 . 15 lb/day of <br /> hydrocarbon It is also recovering CO2 at the rate of 144 lb <br /> hydrocarbon a day, oxidized <br /> R �er <br /> Geologist <br /> CC <br /> Gary Reeves <br /> San Joaquin Valley Unified Air Pollution Control District <br /> 4230 Kiernan Ave #130 <br /> Modesto, CA 95356 <br /> (209) 545-7000 <br /> Mary F Meays <br /> Public Health Services <br /> P.O Box 2009 <br /> Stockton, California 95201 <br /> page 6 of R603 , 08/13/93 <br /> a <br />