Laserfiche WebLink
r <br /> VAPOR SAMPLING <br /> COLLECTING LABORATORY SAMPLES <br /> ' F <br /> Influent Sample <br /> The influent sample is obtained from a sample port located after the. <br /> system vacuum pump before the REMOX Unit . . .Sterile poly tubing . is <br /> then used to attach a 1 liter tedlar bag, , fitted with - a special <br /> septum "valve" and tubing bib, 'to :the sample port . The sample port <br /> is on the pressure side of the pump and therefore the bag will fill <br /> without need of a pump. Once the tedlar bag is filled, , its -valve is: <br /> closed and locked; the appropriate label is placed on the ' tedlar. <br /> bag. <br /> Effluent Sample <br /> A sample port for the effluent is -:,'located in the exhaust stack of <br /> the Remox system. The flow pressure from the exhaust .. is great <br /> i enough to fill a tedlar bag. Sterile poly tubing is fitted to' the <br /> exhaust port and the tedlar bag. Then the sample valve of the �1 <br /> tedlar bag is opened and the bag is filled with the sample. Once <br /> the tedlar bag is full, the valve is closed and locked, the sample , <br /> port closed, and the appropriate label is placed on the bag. <br /> The labels for both the influentnand effluent tedlar bag samples <br /> show the date, time, sample ID## and analyses to be run. <br /> Both the influent and effluent tedlar bag samples are then placed <br /> within a cooler, on ice, and are hand delivered to WEGE.' s laboratory ` <br /> i <br /> that same, day. , <br /> t The vapor sample is. then injected into an FID AFlame -Ionizing'' `-'L` . <br /> Detector), chromatograph and the resulting chromatogram compared . to <br /> standard , chromatograms of . known: TFH (Total Fuel Hydrocarbons,.`: ` <br /> gasoline) and BTEX (benzene, toluene, ethlybenzene, and xylenes). <br /> concentrations . A duel chromatograph comparison is also ran ' <br /> 1 (Photovac. 10S50) to evaluate BTEX, TCE, PCE, and DCE. <br /> ON SITE ANALYSIS <br /> Besides bag samples collected for; the WEGE laboratory some samples <br /> may be run on site using a Photovac 10550 PTD chromatograph. <br /> The influent and effluent • samples are collected from the same. ports '`. <br /> as the bag samples but 60 cc syringes are used to collect the sample, .-, : " <br /> and 0 . 5 cc of the vapor sample are then injected directly into the,`.:. . <br /> PID chromatograph. The resulting chromatogram is then compared to <br /> a standard calibration run on the; same chromatograph prior to the <br /> !! sample run. t <br /> r .. <br /> ' page 3 of R&03 , 04/08/93 <br /> } <br /> . -..,J,,. -:.vim-. ..,..�rr... ...ti .�...-..,,.....,.....�......�w.. �.,..�.. �,.�...-.�...,. .. <br />