INSTALL TANK TOP UPGRADE 1994
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
INSTALL TANK TOP UPGRADE 1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2019 4:31:46 PM
Creation date
8/23/2019 3:55:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
TANK TOP UPGRADE 1994
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A & S ENGINEERING INC. <br /> PLANNING • ENGINEERING • CONSTRUCTION MANAGEMENT <br /> 49 QUAIL COURT, STE. 303, WALNUT CREEK, CA. 94596 • PHONE: 510-933-0578 • FAX 510-933-0588 <br /> r e <br /> 1. 1994 <br /> 5) Comment: Is the piping system a pressure system? Please clarify. L. HEALTH <br /> Response: The piping system is a pressure system. PERMI i/SERVICES <br /> 6) Comment: All equipments, including the sensor probes, must be compatible. <br /> submit confirmation and/or verification. <br /> Response: All equipment is compatible. See attached Veeder-Root monitoring <br /> system cut-sheets. <br /> 7) Comment: When the alarm is activated or when the system fails the pump must <br /> be completely shut off. Submit verification. <br /> Response: The Veeder-Root system can be programed to do this if you are <br /> referring to the line sensor and/or sump sensor. <br /> 8) Comment: Provide the sensor probe in the dispenser sump. Submit <br /> specification and brochure to EHD. <br /> Response: Please see attached cut-sheets for dispenser sump sensors. <br /> 9) Comment: The secondary flex hose is allowed under the dispenser as the last <br /> connection only. Submit confirmation. <br /> Response: The secondary flex hose under the dispenser will be the last <br /> connection as requested. <br /> Please process these corrections as soon as possible. I have also enclosed(3)revised prints of <br /> drawing#T-4 equipment list. The main revision was changing the monitoring system to <br /> Veeder-Root. Feel free to call me if you have any questions or comments. It is important that we <br /> obtain this permit as soon as possible, so we would appreciate your cooperation in this matter. <br /> Sincerely ours, <br /> Vince Padi <br /> A&S Engineering <br /> 207 W. ALAMEDA AVE., STE. 202 9 BURBANK, CA 91502•TELEPHONE: 818-842-3644• FAX:818-842-3760 <br />