TABLE III <br />Termination Fittings Connections <br />Termination <br />Concentric Reducer <br />Size Large End Fits Small End Fits <br />3"x2' 3' Pipe 2' Male Threaded Adapter or coupling <br />4"x2" 4' Pipe 2" Male Threaded Adapter or coupling <br />4"x3" 4" Pipe 3' Male Threaded Adapter or coupling <br />6"x4" 6' Pipe 4" Pipe <br />NOTE: All other secondary containment fittings are manufactured to fit the O.D. of contain- <br />ment piping. <br />Standard U.L. male threaded adapters or couplings must be san- <br />ded to fit the secondary containment fittings. See Figure 7. <br />Special 2" male adapters for secondary containment (which have <br />been machined to fit) are also available. <br />Sand O.D. of adapter or coupling <br />so that the reducer halves <br />fit together when assembled <br />by hand. <br />— <br />It there is a gap between <br />the reducer halves when assembled <br />by hand, more sanding is required. <br />Figure 7 <br />Dispenser <br />Impact Valve <br />_ Gasoline Resistant Boot <br />L Flexible Connector <br />Figure 8 <br />Dispenser <br />Impact Valve <br />Fiberglass <br />Threaded Adapter <br />(Bell x Male) <br />Flexible <br />Connector <br />Figure 9 <br />4 <br />SECTION IV <br />CONTAINMENT CROSSOVER DETAIL <br />When installing a Smith Fiberglass Products containment system, <br />some preparation is necessary if the closest possible separation of <br />lines is required. It is necessary to shorten one leg of the 45° contain- <br />ment elbow and the side run of the containment tee. <br />Refer to Table IV for the maximum length that can be removed and <br />for the minimum nipple length of both product piping and contain- <br />ment piping. <br />TABLE IV <br />Containment Remove from Remove from Product' Containment <br />Pipe Size 45° Crossover Ell Side Run -Tee Nipple Size Nipple Size <br />(In.) Max. In. Max. In. Min. In, Min, In. <br />3 1.25 1.50 2 x 8 3 x 6 <br />4 2.00 1.63 3 x 8 4 x 6 <br />6 1.25 1.00 4x10 6 x 8 <br />Actual length of the product nipple will vary slightly because of different insertion lengths <br />due to variations in tapers. <br />To prevent interference of the pipe lines, do not locate two <br />containment fittings closer than shown in Figure 10. <br />NOTE: Match drill 2 holes (5/16" diameter) at a distance of 3/4" from <br />the cut end of the 45' ell and the tee. / <br />NOTE: The 2.5" critical dimension must be inspected in the field. <br />Figure 10 <br />Containment <br />Pipe <br />A <br />B <br />C <br />D <br />E <br />(In.) <br />(in.) <br />(In.) <br />(In.) <br />(In.) <br />(In.) <br />3 <br />7.5 <br />10.6 <br />6.5 <br />10 <br />14.5 <br />4 <br />8.5 <br />12 <br />7.5 <br />12 <br />16.5 <br />6 <br />10.65 <br />15 <br />8 <br />14.75 <br />22 <br />10M 488 Printed in USA <br />