My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 1985 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:49:43 AM
Creation date
8/26/2019 9:14:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985 - 2004
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
507
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC HIALTH SERVIC 'S <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DIVISION <br />Karen Furst, M.D., M.P.H., Health Officer <br />304 East Weber Avenue, Third Floor • Stockton, CA 95202 <br />209/469-3424 <br />APPLICATION FOR PERMIT TO CLOSE <br />UNDERGROUND STORAGE TANKS STORING HAZARDOUS MATERIALS <br />GENERAL INSTRUCTIONS: <br />N- <br />1. Submit all information in triplicate. Answer all questions, leaving no blanks. One copy will be returned <br />to the applicant with comments. <br />2. include a detailed site map on a separate sheet of paper, showing the location of the tanks(s), piping, <br />streets, adjacent properties (north toward the top of the page), nearby septic tanks, leachfields, water <br />wells, buildings, underground public utility lines (including water, sanitary sewer and storm sewer), and <br />distance of piping from tank to dispensers. If underground utilities are not included on the site map, you <br />must state in writing that USA Dig will be contacted prior to excavation activities. <br />3. Complete page 3, "Application for Underground Storage Tank Closure Permit". Not : Sampling <br />firm shall be an independent third party from the contractor. <br />4. Complete page 9, "Authorization to Release". This form must be signed and dated by the <br />OWNER/OPERATOR of the facility. <br />5. Submit the appropriate fees and complete page 11, the "Underground Storage Tank Program Fee <br />Worksheet". <br />6. Complete all questions on page 10, the Public Health Services -Environmental Health Division (PHS- <br />EHD) "Underground Storage Tank Disposition Tracking Record", except those requiring a signature <br />and date of tank removal. The holder of the permit shall be responsible for ensuring that this form is <br />completed and returned to PHS-EHD within 30 days of the tank removal. <br />X 7. Submit a "Site Health & Safety Plan" as an addendum to this application, to address all potential <br />hazards for this specific job site. Refer to the Site Safety Plan Guidance Document for specifics. <br />t4 8. If facility is located outside of the city limits, submit a 'Backfill Excavation Certificate" as required by <br />the County of San Joaquin Building Department and the incorporated City Building Departments, <br />pursuant to the Uniform Building Code STD 70-11. <br />N/A [] 9. Obtain a "Grading and Excavation Permit" from the City of Tracy Building Division prior to PHS- <br />EHD approval of the closure plan. <br />fj 10. The maximum review time for Closure Plans is 15 working days from receipt of the adequately <br />completed plan. If gross deficiencies are identified, an addendum will be required with a $78.00/hour <br />fee and the review will begin on the date of resubmittal. <br />Submit verification of the fire permit from the appropriate fire district at the removal inspection. <br />12. Advance inspection notice of at least 48 hours is required by PHS-EHD. <br />NIA [] 13. Submit Contingency PIan for over -excavation at time of UST removal (if planning to over -excavate). <br />See "III. SITE MITIGATION" on Page 2. <br />EH 23 046 (Revised 08/13/99) Page i <br />A Division of San loaouin Countv Health Care Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.