Laserfiche WebLink
Monitoring System Certification - P: 43 <br /> Site Address: 4315 Waterloo Rd. @ Hwy. 99 Date of Testing/Servicing: 5/26/04 <br /> D. Results of Testing/ Servicing <br /> Software Version Installed: 119.02 <br /> Complete the following checklist: <br /> ®Yes ❑ No* Is the audible alarm operational'? <br /> IN Yes ❑ No* Is the visual alann operational'? <br /> ®Yes ❑ No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> ®Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation'? <br /> ®Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> ❑ N/A operational? <br /> ®Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) ®Sump/Trench Sensors; ®Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ®Yes ❑No <br /> ❑Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> IN N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 0 % <br /> ❑Yes* ® No Was any monitoring equipment replaced?If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑ Water. If yes,describe causes in Section E,below. <br /> ®Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? Attach set-up reports. if applicable.) <br /> ®Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * in Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br />