Laserfiche WebLink
America)v Environmental Network <br /> WORK ORDER: 9712296 QUALITY CONTROL REPORT PAGE QR-2 <br /> ANALYSIS: Gasoline Oxygenates <br /> MATRIX: Water <br /> METHOD BLANK SAMPLES <br /> ----------------------------------------------------------------------------- --------- -------------------••--------------- <br /> SAMPLE TYPE: Blank-Method/Media blank LAB ID: BLNK_1229 INSTR RUN: GCMS13\971229000000/1/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W123097 <br /> UNITS: ug/L ANALYZED: 12/29/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPO <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCE-d4 (surr) 86,2 100 100 86.2 70 130 <br /> Toluene-d8 (surr) 103 100 100 103 70 130 <br /> Bromofluorobenzene (surr) 78.9 100 100 78.9 70 130 <br /> Methy-t-butyl ether (MTBE) ND 5 <br /> Ethyl-t-butyl ether (ETBE) ND 5 <br /> t-Amylmethyl ether (TAME) NO 5 <br /> t-Butanol (TBA) NO 100 <br /> Di-isopropyl ether (DIPE) ND 5 <br /> --------------------------.........................----------------•----•................................................ <br /> LABORATORY CONTROL SAMPLES <br /> ---------------------------------------------------------------•--- ........................................... ---------- <br /> SAMPLE TYPE: Laboratory Control Spike LAB ID: LCSW_1229 INSTR RUN: GCMS13\971229000000/2/1 <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: M513WI23097 <br /> UNITS: ug/L ANALYZED: 12/29/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2.OCE-d4 (surr) 94.8 86.2 100 100 94.8 70 130 <br /> Toluene-d8 (surr) 103 103 100 100 103 70 130 <br /> Bromofluorobenzene (surr) 76.9 78.9 100 100 76.9 70 130 <br /> -'` Methy-t•butyl ether (MTBE) 122 NO 5 100 122 32 158 <br /> Ethyl-t-butyl ether (ETBE) 142 ND 5 100 142 32 158 <br /> t-Amylmethyl ether (TAME) 101 ND 5 100 101 32 158 <br /> --------------------- --------------•-•-----..........---------------------------------- ----- ........ <br /> SAMPLE SURROGATES <br /> ---------------------- ......--•---------------------------------------•-- ................................... <br /> SAMPLE TYPE: Sample-Client LAB ID: 9712296.01C INSTR RUN: GCMS13\971229000000/16/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W123097 <br /> UNITS: ug/L ANALYZED: 12/30/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RAD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCE-d4 (surr) 81.3 100 100 81.3 70 130 <br /> Toluene-d8 (surr) 96.9 100 100 96.9 70 130 <br /> Bromofluorobenzene (surr) 89.1 10.0 100 89.1 70 130 <br /> --------•...................•----------------------------------------- ....................................... -------------- <br /> .............•-------------------------------------------- •-•---•---•--•--------------------------------•------------- <br /> SAMPLE TYPE: Sample-Client LAB ID: 9712296-02B INSTR RUN: GCMS13\971229000000/13/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W123097 <br /> UNITS: ug/L ANALYZED: 12/30/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCE-d4 (surr) 85.6 100 100 85.6 70 130 <br /> Toluene-d8 (surr) 99.6 100 100 99.6 70 130 <br /> Bromofluorobenzene (surr) 87.6 100 100 87.6 70 130 <br /> - <br /> -----------------------------------••---- ---------............-•----------------------------------------------------------- <br /> -------------------------•...........--------••-------........---••-------------------......--------------------------------- <br /> SAMPLE TYPE: Sample-Client LAB ID: 9712296-03B INSTR RUN: GCMS13\971229000000/14/ <br /> INSTRUMENT: HP mass spec for Volatiles PREPARED: BATCH ID: MS13W123097 <br /> UNITS: ug/L ANALYZED: 12/30/97 DILUTION: 1.00 <br /> METHOD: <br /> REF REPORTING SPIKE RECOVERY REC LIMITS (X) RPD <br /> ANALYTE RESULT RESULT LIMIT VALUE (X) LOW HIGH RPD (X) LIMIT (X) <br /> 1,2-DCE-d4 (surr) 87,8 100 100 87.8 70 130 <br /> Toluene-d8 (surr) 98.5 100 100 98.5 70 130 <br /> Bromofluorobenzene (surr) 88.1 100 100 88.1 70 130 <br /> ----------------------------------------•--•......................................................................... <br /> i <br />