Laserfiche WebLink
Mr. Ed Ralston -2 - 23 October 2007 <br /> Former Unocal Bulk Plant, Tracy• <br /> about nine feet bgs. Petroleum hydrocarbons and fuel oxygenates were not detected in any of <br /> the samples. <br /> The Domestic Well Report describes the sample results for the onsite water supply well. On <br /> 23 March 2007, ConocoPhillips collected a sample from the water hose connected to the hose <br /> bib after purging the water for two minutes and TPHd was detected at 140 pg/L. On <br /> 4 April 2007, ConocoPhillips collected a sample from the bib/tap after disconnecting the hose, <br /> sterilizing the tap, and purging the water for five minutes. TPHd was detected at 110 Ng/L; <br /> however, the analytical laboratory noted that the chromatograph was not typical for diesel. <br /> The laboratory also flagged the results because laboratory surrogate recoveries were not <br /> within the control limits, matrix spike precision for TPHd was not with in the control limits, and <br /> TPHd was detected in the method blank. On 16 April 2007 and 27 April 2007, ConocoPhillips <br /> collected samples from the bib/tap after the water was purged for 30 minutes which emptied <br /> the holding tank and allowed the pump to run. TPHd was not detected in these samples. <br /> On 1 October 2007, ConocoPhillips emailed Regional Water Board staff the August Results. <br /> Groundwater samples were collected on 29 August 2007 from wells U-8 and U-9 and analyzed <br /> for TPHd. TPHd was detected in U-8 and U-9 at 56 pg/L and 47 pg/L, respectively. Both <br /> results were flagged because of the 40 pg/L detection in the method blank. <br /> Historical Site data show that petroleum hydrocarbon concentrations are below or near <br /> detection limits, with the exception of the data with laboratory flags. Regional Water Board <br /> staff review of the case file shows that Regional Water Board staff requested a Closure Report <br /> in an 8 July 2005 email. By 30 November 2007, please prepare a Closure Request Report <br /> that complies with the No Further Action documentation requirements in the 16 April 2004 <br /> Appendix A Tri Regional Board Staff Recommendations for Preliminary Investigation and <br /> Evaluation of Underground Storage Tank Sites. <br /> If you have any questions regarding this letter, you may contact me at (916) 464-4819 or by <br /> email at ksheltonpwaterboards.ca.gov. <br /> KRISTI SHELTON <br /> Water Resources Control Engineer <br /> Aboveground Tanks Cleanup Unit <br /> cc: Ms. Margaret Lagorio, San Joaquin County Environmental Health Department, Stockton <br /> Ms. Diane Barclay, SECOR, Rancho Cordova <br />