May 14, 1990 <br /> Project 310-01.02 <br /> Page 3 <br /> of interbedded clay, silt, sand, and gravel. Groundwater-:-flow <br /> direction beneath the site is anticipated. to be northeasterly; <br /> based on the regional groundwater flow direction and regional <br /> topography. <br /> WELL SURVEY <br /> A water supply well survey was conducted through the Department <br /> of Water Resources (DWR) to identify known water supply wells <br /> located within a one-half mile radius of the site. A total of <br /> nine"water- supply :wells were located withinthe one-half mile <br /> radius., and are summarized on Table 1. The wells are used for <br /> domestic and agricultural purposes. An additional three wells <br /> were identified that may be located within the ane-half mile 3 <br /> radius, however the DWR records do not indicate the precise <br /> location. These three wells are used for domestic purposes. <br /> The well closest to the site for which PACIFIC has a location is <br /> designated Well G on Figure 1. This well is located { <br /> approximately 600 feet southeast of the site and is used for <br /> domestic purposes. <br /> { <br /> PROPOSED SCOPE OF WORK <br /> Due to the petroleum hydrocarbons noted in the soil sample <br /> collected from beneath the former transmission fluid tank, <br /> PACIFIC !initially. proposes.the:installation `of three'groundwater <br /> monitoring wells,-to investigate the•vertical'and'lateral'.extent <br /> of_hydrocarbons •in: the,:soil:.and .groundwater: The proposed well <br /> locations are shown- on Figure 2. <br /> One well is to be placed immediately adjacent to the former tank <br /> ! excavation to document soil and groundwater conditions adjacent <br /> to and beneath the former tank location. This well is proposed <br /> in the area of detected hydrocarbons. The two other proposed <br /> wells will be placed downgradient (inferred northerly gradient) <br /> of the former tank location to characterize downgradient <br /> groundwater conditions as well as assist in estimating the <br /> lateral extent of .hydrocarbons in the soil. ]Exploratory <br /> drilling and monitoring well installation procedures are <br /> presented in Attachment A. <br /> Laboratory Analysis <br /> ------ --All-groundwater_.samples__and_sele.cte.. l_samples will be_..._...__... <br /> analyzed in. a state certified laboratory for low bol - <br /> — ------ <br /> hydrocarbons (calculated as gasoline) including benzene, <br /> toluene, ethylbenzene, and xylenes, and high-boiling <br /> t-- hydrocarbons as transmission fluid, diesel, and oil. <br /> Attachment B presents the analytical methods and typical <br /> detection limits. <br /> IT . <br />