Laserfiche WebLink
December 4, 2012 Lab ID : STK 1250809 <br /> Luhdorff& Scalmanini, Consulting Eng. Customer 3-12023 <br /> Quality Control - Inorganic <br /> 'omliluent Method Date/dD 'rvpe Units Conc. Q( Data UQO Note <br /> \i t Chem <br /> !41r,�ic 300.0 11/21112:213122CHL MSRPD ingil. 100,0 1.4% _4f <br /> 300.0 11121/12:217377CHL CCB ppm 0.134 0.4 <br /> CCV ppm 20.00 101% 90-110 <br /> CCA ppm 0.153 0.4 <br /> CCV ppm 20.1X1 101 % 90-I 10 <br /> CCD ppm 0.158 0.4 <br /> CCV m 20.00 1 101% 90-110 <br /> NOW, 300.0 11121/12:213122CHL LCS mg/L 15.00 104% 90-110 <br /> MS mg/L 300.0 101% 87-115 <br /> (VI 1242858-001) MSD mg/L 300.0 102% 87-115 <br /> MSRPD m /L 100.0 0.4% <9 <br /> 300.0 11/21112:217377CHL CCB ppm -0.250 0.3 <br /> CCV ppm 15.(81 104% 90-110 <br /> CCB ppm -0.247 0.3 <br /> CCV ppm 15.00 102% 90-110 <br /> CCB ppm -0.250 0.3 <br /> CCV plain 15.00 106% 90-110 <br /> UH,itc 300.0 I V21/12:213122CHL LCS mg/L 50.00 101% 90-110 <br /> MS mg/L 1000 104% 92-113 <br /> (VI 1242858-00I) MSD mg/L 1000 103% 92-113 <br /> MSRPD mg/L 100.0 0.5% 4 <br /> 300.0 11/21/12.217377CHL CCB ppm -0.04 2 <br /> CCV ppm 50.01 103% 90-110 <br /> CCB ppm 0.20 2 <br /> CCV ppm 50.0(1 102% 90-110 <br /> CCB ppm -0.03 2 <br /> CCV PPM 50.00 103% 90-110 <br /> slit 554110 l l/21/12:2173I3jmg CCB mg/L 0.000 0.1 <br /> CCV mg/L 10.00 100% 99-101 <br /> Wit n1'screoi S 540 MS mg/L 10.(1(1 100% 90-110 <br /> (VI 1242813-004) MSD mg/L 10.00 100% 90-110 <br /> MSRPD mg/L I 10.00 (1(/ <0.1 <br /> DeBnifian <br /> ICB Initial Calibration Blank-Anal.7ed to verify the instrument baseline Is within criteria. <br /> CCV Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is nos contributing contamination to the samples. <br /> LCS : laboratory Control Standard Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recover, <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analytcd.The movencs <br /> arc an indication of how that sample matrix affects analyte recovery. <br /> Dup :Duplicate Sample-A random sample with each batch is prepared and analyzed in duplicate.The relative percent differtawe is an <br /> indication of precision for the pnpamtion and analysis. <br /> MSRPD :MSfMSD Relative Percent Difference(RPD)-'rhe MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> No :Non-detect-Result was below the DOD listed for the analyte. <br /> 1222 Data Quality Objective-This a the criteria atisainst which the quality control data is compared. <br /> Explanation <br /> 360 C('V above Acceptance Range,.ARI.Samples which were non detect fix this analytic wcrc accepted. <br /> 435 Sample mains may be affecting this analyte.Data was accepted based on the LCS or('('V recovery. <br /> 440 Sample nondicanogenciiX may he affecting this anal e.Data was accepted based on the LCS or CC'V recovery -- <br /> Page 10 of 10 <br />