My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011609 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1640
>
2600 - Land Use Program
>
PA-1700271
>
SU0011609 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:18 AM
Creation date
9/4/2019 10:40:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0011609
PE
2625
FACILITY_NAME
PA-1700271
STREET_NUMBER
1640
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
AVE
City
STOCKTON
Zip
95205-
APN
14325012
ENTERED_DATE
12/21/2017 12:00:00 AM
SITE_LOCATION
1640 N BROADWAY AVE
RECEIVED_DATE
12/18/2017 12:00:00 AM
P_LOCATION
99
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BROADWAY\1640\PA-1700271\SU0011609\SS_NL STUDY .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Wong and indicates a percolation rate for the hole based on the final <br /> water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. For the <br /> Site to utilize a standard septic system, one percolation test must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field. <br /> Details and results of the percolation testing are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, Satisfactory perc. <br /> 2/20/2018 3.00 19.2 4 hr. rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow"test is less than or equal to 60 minutes per inch. <br /> • Discussion of Percolation Test Results <br /> The soil within the sewage disposal area of the Site has demonstrated a satisfactory <br /> percolation rate for the use of a standard septic system in accordance with the <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and seepage pits should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2016) where <br /> applicable. <br /> • LOGE 1806 Page 6 <br />
The URL can be used to link to this page