Laserfiche WebLink
1 <br /> Item No. 3 <br /> {� PC. 12-17-92 <br /> t SU-92-15 <br /> Page 1 <br /> RECOMMENDATION <br /> It is recommended that the Planning Commission: ' <br /> G <br /> 1. Deny Major Subdivision Application No. SU-92-15 because Finding No. 2 and Finding No. 6 <br /> cannot be made. <br /> FINDINGS <br /> 1. The proposed subdivision is consistent with the General Plan, any applicable Specific Plan and <br /> Special Purpose Plan, and any other applicable plan adopted by the County. <br /> • This Finding can be made because the proposed subdivision is consistent with the <br /> 4 2010 General Plan and the Policies of the Rural Residential designation on the <br /> General Plan Map. There are no Specific or Special Purpose Pians. <br /> 2. The design or improvement of the proposed subdivision is consistent with the General Plan and <br /> any applicable Specific Plan or Special Purpose Plan. <br /> • This Finding cannot be made because the design of the proposed subdivision does <br /> not meet the minimum lot width requirements, and the design of the proposed <br /> f subdivision does not provide traffic circulation that Is consistent with the <br /> Infrastructure Standards and Requirements of the Development Title. The minimum <br /> lot width requirement at the setback is 150 feet. Several of the lots do not meet the <br /> minimum width, and they do not meet the provision that allows the minimum lot width <br /> to be 70 percent of the required lot width, provided the average lot width for all lots <br /> in the subdivision Is equal to or greater than the minimum lot width. The <br /> Development Title slates that a cul-de-sac street shall not exceed 660 feet from the <br /> centerline of the Intersecting street to the center of the turnaround except where <br /> existing physical conditions make such limitations of length impractical. In no case <br /> shall more than 24 dwelling units be served by a cul-de-sac street. The design of the <br /> subdivision proposes cul-de-sac streets that exceed the 660 feet maximum length, <br /> and there is the potential for more than 24 dwelling units to be served. Unless the <br /> design of the cul-de-sac streets complies with the requirements of the Development <br /> Title, any lot within the subdivision must be reached by alternative routes. <br /> 3. The site is physically suitable for the type of development. <br /> • This Finding can be made because the proposed lots have sufficient areas to build <br /> residences and septic systems. <br /> 4. The site is physically suitable for the proposed density of development. <br /> • This Finding can be made because each lot in the subdivision will meet the area <br /> requirement of the R-R zone. Services will be provided to each lot In accordance <br /> with the County's Infrastructure Standards. <br /> i <br />