s.. Mr.George Rose <br /> August 21,2001 <br /> Page 3 <br /> The percolation rate was found to be rapid:in most of the deep percolationtests..The°permeable layer , <br /> is typically sandy,thin,and bounded by less permeable layers. The surface soils are low permeability,often <br /> containing dark clay soils,which provide optimum conditions for denitrification within leach lines.Due to <br /> the highly heterogeneous'soils,the deep depth.to ground water,clayey surface soils,we do not believe that <br /> the rapid percolation rate will cause a buildup of nitrates in ground water above 10-mg/L=N. This issue was . <br /> discussed in more detail in the Addendum letter dated November 27,2000. <br /> After a review ofprevious work conducted at the site and work comp <br /> during this effort,we have <br /> concluded that the new parcels are suitable for use with a septic system using,leach lines-and seepage pits. <br /> The soil suitability/nitrate loading study,dated October 12, <br /> 2000,the addendum letter dated November 27, <br /> 2000,and the addenduim letter dated April 12, 2001 indicate' development density of 2.0 acres or greater <br /> is suitable for the area and will not cause abuildup of nitrates' the groundwater above safe drinking water . <br /> levels established by the Environmental Protection Agency OA): All the new lots are greater than-2-acres <br /> in size and therefore satisfy this requirement_ We recommend that the San Joaquin County.Public Health <br /> Services Sewage Standards are followed <br /> Limier S <br /> The summary and conclusions -of this addendum letter are based on the-information provided <br /> regarding the existing and proposed development,the use of the subject property,and the site conditions as - <br /> they existed at the time we excavated our test holes and performed the percolation test. It was assumed that <br /> the test holes and percolation test results are representative of the subsurface conditions in the general area. <br /> Our professional services were performed,our findings obtained,and-our,conclusions proposed in <br /> accordance with generally accepted engineering principles and practices. This warranty is in'lieu of all other <br /> warranties either expressed or implied. Test findings and statements of professional opinion do not <br /> constitute a guarantee or warranty,expressed or implied. . <br /> ��D GOC <br /> Best regards, <br /> 1 <br /> S <br /> I No.211 y NEIL O. ANDERSON&ASSOC.,INC. <br /> CERTIFIED M <br /> • ENGINEERING <br /> if►�, GEOLOGIST <br /> g�4FGA�- David J.Welch,M.Sc..;Senior Geologist <br /> CEG-2151,CHG-653 <br /> Garret S.H.Hubbart,M.Sc. <br /> DJW,GSHH-djw CC c� Civil Engineer No. 59010 <br /> FESS <br /> Q�O /O <br /> o � <br /> No. � rn <br /> Exp.6103, <br /> )F CAtIF� . <br />