Laserfiche WebLink
Smith Environmental Site Safety Plan <br /> ❑ Confined Space Entry (follow Smith Environmental's Confined Space Entry Procedures) <br /> r ❑ Other - explain hazard and mitigation <br /> 4 <br /> EXPOSURE MONITORING <br /> All sample results will be recorded in the Smith Environmental exposure log. Log copies are filed in the <br /> r job file, and in all site personnel's medical file, and maintained in the job file. All sampling instruments <br /> j4r will be calibrated per the manufacturers instructions on a daily basis. <br /> *Note calibration gas and any unusual calibration settings in the "monitoring equipment" column. <br /> **Include monitoring for health hazards, explosion hazards, etc. <br /> C Monitoring Hazard Sample Sample Action <br /> IL Equipment Monitored Location Frequency Level Action <br /> OVM/PID Organic Vapors Ambient Air 20 ppm* Level C w/1/2 <br /> or full face <br /> respirator <br /> OVM/PID Organic Vapors Ambient Air >200 ppm Evacuate <br /> Site <br /> * Benzene is not specifically monitored for with a OVM so any vapor reading at 20 ppm must require <br /> 1/2 face respirator. <br /> Identify sample locations on site map. <br /> PACE 6 <br /> !r <br />