My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
8111
>
3500 - Local Oversight Program
>
PR0544804
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:51 AM
Creation date
9/4/2019 1:31:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0544804
PE
3528
FACILITY_ID
FA0003850
FACILITY_NAME
M&M BUILDERS SUPPLY INC
STREET_NUMBER
8111
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95304
APN
25014006
CURRENT_STATUS
02
SITE_LOCATION
8111 W ELEVENTH ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wright <br /> Environmental — <br /> Services, Inc. <br /> Construction ♦ Engineering ♦ Remediation <br /> ENVIRONMENTAL HEALTH DIVISION <br /> 304 E. Weber Ave. Third Floor ® ��g9 <br /> _ P. O. Box 388, Stockton CA 95201-0388 DEC 1 <br /> December 8, 1999 ' c-,_ <br /> - Approved ❑ �ivra,La h <br /> Denied ENVIRO' \'iE 's;e'- <br /> Conditions PERMS f � <br /> Mr. Shawn Kelley <br /> M&M Builders Supply Date i 3 by__ <br /> P.O. Box 1107 <br /> Tracy, CA 95378-1107 <br /> Re: Workplan for Environmental Subsurface Site Investigation, <br /> M&M Builders Supply,8111 W. Eleventh St.Tracy,CA 95376 <br /> Wright Project No.4669 <br /> PHS-EHD,Site Code: 1530 <br /> Dear Mr.Kelley, <br /> Wright Environmental Services, Inc. (Wright) is pleased to provide you with this workplan for the <br /> environmental investigation at the above referenced site (see Figure 1). The purpose of this work is to <br /> ascertain presence of suspected petroleum contaminants in soil and groundwater around the former tank <br /> area as required by the San Joaquin County, Public Heaith Services -Environmental Health Division <br /> (PHS-EHD)in their letter dated August 16, 1999. <br /> BACKGROUND <br /> Two underground fuel storage tanks (Tank#1 1,000 gallon diesel; Tank#2 1000 gallon gasoline;) were <br /> used by M&M Building Supply until their removal from the site on August 8. 1988 and June 23,1994 <br /> respectively, (see Figure 1). One soil and one grab groundwater sample were collected from the tank pit <br /> of T-1. Analysis of the soil evidenced 8,700 parts per million(ppm)Total Petroleum Hydrocarbon(TPH), <br /> .8-ppm benzene, 1.4-ppm toluene and 1.1-ppm xylene. Analysis of the water evidenced 56,000-parts per t- .%\ l0 <br /> t'il1i�=TPH, 11,000-ppb benzene, 3,100-ppb toluene and 7,200-ppb xylene. Four wil samples and <br /> one grab groundwater sample were collected for analyses subsequent to removal o T-2. o soil samples <br /> \ <br /> from the bottom of the tank pit were reported as non-detectable for TPH and two soil samples collected <br /> from the stockpile and analyzed, evidenced very minor TPH contamination. The water sample collected_ _. <br /> from the tank pit and analyzed evidenced 11,000-ppb TPH as gas (TPHg);I10-ppb ethyl benzene_' On <br /> July 28, 1994 another water sample was collected, analysis resulted in non-dzTectable results for TPH <br /> constituents. Methods of purging groundwater(if performed) from the former tank pit prior to collecting <br /> groundwater sample apparently were not forwarded to PHS-EHD for evaluation prior to their issuing (if <br /> warranted) final closure of T-2 site. Current Law requires all sites to be tested for methyl tertiary butyl <br /> ether(1VrIBE)prior to issuance of a notification of closure by PHS-EHD. <br /> The PHS-EHD indicated that further assessment work was needed to ascertain contaminant source,lateral <br /> and vertical extent and impact to soil and groundwater. In addition, PHS-EHD has required a well <br /> survey, which documents the locations of all domestic, municipal, industrial, agricultural and other wells <br /> within a 2,000-foot radius of the site. One domestic water supply well exists on the site. Application for <br /> reimbursement from the State Water Resources Control Board UST Clean Up Fund has not been filed for <br /> this site. <br /> 67 E. 10th Street . Tracy, CA 95376 <br /> 209.833.0758 . Fax 209.832.5152 <br /> wright(a�inreach.com Lic. #651501 .1-3 HazMat <br /> websit http:Glhome.inreach.comiivright <br />
The URL can be used to link to this page
Your browser does not support the video tag.