r r-4_ <br /> LABORATORY NARRATIVE <br /> Modified TO-3 . <br /> Geological Technics <br /> Workorder#0312207 <br /> Two 1 Liter Tedlar Bag samples were received on December 11, 2003. The laboratory performed analysis <br /> C, for volatile organic compounds in air via modified EPA Method TO-3 using gas chromatography with photo <br /> ionization and flame ionization detection. The method involves concentrating up to 200-mL of sample. The <br /> concentrated aliquot is then dry purged to remove water vapor prior to entering the chromatographic system. <br /> The TPH (Gasoline Range)results are calculated using the response factor of Gasoline and correspond to the <br /> range of hydrocarbons from C5 to C 10. A molecular weight of 100 is used to convert the TPH (Gasoline <br /> Range)ppmv result to ug/L. See the data sheets for the reporting limits for each compound. <br /> Method modifications taken to nm these samples include: <br /> Requirement TO-3 ATL Modifications <br /> Daily Calibration Standard Prior to sample analysis Prior to sample analysis and after the analytical batch</=20 <br /> Frequency and every 4-6 hrs samples <br /> Initial Calibration Calculation 4-point calibration 5-point calibration using average Response Factor <br /> + using a linear <br /> regression model <br /> Initial Calibration Frequency Weekly When,daily calibration standard recovery is outside 75 - 125 <br /> %,or:upon significant changes to procedure or <br /> 'instrumentation <br /> Moisture Control Nafion system Sorbent system <br /> t Minimum Detection Limit(MDL) Calculated using the 40 CFR Pt. 136 App. B <br /> equation DL=A+3.3S, 4 <br /> where A is intercept of <br /> calibration line and S is <br /> the standard deviation <br /> r of at least 3 reps of <br /> low level standard <br /> Preparation of Standards Levels achieved Levels achieved through loading various volumes of the ga; <br /> j through dilution of gas mixture <br /> Lmixture <br /> Receiving Notes <br /> There were no receiving discrepancies. <br /> { <br /> 3 Analytical Notes <br /> i There were no analytical discrepancies. <br /> Definition of Data Qualifying Flags <br /> Seven qualifiers may have been used on the data analysis sheets and indicate as follows: <br /> { B - Compound present in laboratory blank greater than reporting limit._ <br /> 4 J- Estimated value. <br /> 1 E - Exceeds instrument calibration range. <br /> { S - Saturated peak. <br /> Q - Exceeds quality control limits. <br /> 3 Page 2 of 7 <br /> �. 1 <br />