My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0000048 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DAVIS
>
11363
>
2600 - Land Use Program
>
MS-00-25
>
SU0000048 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:27:36 AM
Creation date
9/4/2019 5:18:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0000048
PE
2622
FACILITY_NAME
MS-00-25
STREET_NUMBER
11363
Direction
N
STREET_NAME
DAVIS
STREET_TYPE
RD
ENTERED_DATE
8/8/2001 12:00:00 AM
SITE_LOCATION
11363 N DAVIS RD
RECEIVED_DATE
7/17/2000 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DAVIS\11363\MS-00-25\SU0000048\SS STUDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[51 CONCLUSIONS <br /> 77dep'ths <br /> ult for Parcel 1 suggests there will be excellent effluent percolation at deeper <br /> e typical shallow leachline depth of 42 inches. This deep test depth of 9 ft can be <br /> considererepresentative of percolation that would take place in sump-type septic structures. <br /> Although there was percolation within the shallow test boring, which indicates that leachlines in <br /> this locale can manage effluent, it was evident that percolative capacity decreases with soil <br /> saturation. It is important to note that all septic systems have a lifespan. This lifespan is <br /> dependant on several factors and is therefore difficult to determine. From the number of repairs <br /> and additions done in the study area, it is evident that septic systems within this area have a <br /> limited lifespan. <br /> It is recommended that if any structure with a septic system is built on the Designated <br /> Remainder, there must be a percolation test done in the area of the proposed leachfield. A <br /> shallow perc test at 42 inches should be conducted in the proposed leachfield area, along with a <br /> deeper test representative of sumps or seepage pits. With concurrence from the Environmental <br /> Health Department, sumps may be preferable to seepage pits since there would only be a 10 ft <br /> separation distance between the floor of a 25-ft pit and the static water table. Sumps would allow <br /> a greater "treatment" distance. In addition, the leachfield must be hydraulically protected during <br /> the rainy season to prevent inundation. A 50% standby replacement area must be incorporated <br /> into the design. All related septic system structures and a possible new domestic well must <br /> comply with the published "distance" requirements from property borders,roads, irrigation fields, etc. <br /> As noted on the attached Leachline Requirement Map,the subject property is just over the border <br /> of the silt/sandy clay soil area. The map indicates that sumps or seepage pits are allowed in this <br /> area. <br /> Septic system leachline failure would primarily result from the advanced formation of a "biomat" <br /> or "clogging mat" on the wetted soil/effluent interface. This mat is composed mostly of aerobic <br /> and anaerobic bacteria and bacterial products consisting of a slime of polyuronides and <br /> polysaccharides. If the soil/effluent interface is well aerated, a variety of soil microfauna such as <br /> nematodes and protozoa may digest the clogging mat bacteria. Since the shallow subsurface <br /> soils consist mostly of tight, silty type soil material, anaerobic conditions may prevail over time <br /> which may theoretically hasten leachline failure. It is assumed that this accounts for the high <br /> number of system failures in this area. Therefore, seepage pits or preferably sumps must be <br /> installed. <br /> The nitrate concentrations determined in the underlying groundwater suggests there has been <br /> very low impact to the deep aquifers and can possibly be considered background nitrate levels. <br /> Regardless of the nitrate concentration of any well water in rural areas, it is recommended that <br /> bottled water should always be used for drinking and cooking purposes. <br /> 4 <br /> Va&y Ag Research <br />
The URL can be used to link to this page
Your browser does not support the video tag.