May 3, 1999 <br /> Soil Suitability Study (APN 255-230-20)Cont. <br /> Soil Profile. <br /> A soil profile was performed on Lot No 1 and on Lot No <br /> 5'A saturated condition was encountered at 14' on Lot No. I and <br /> water was encountered at 16' on Lot No.f See the percolation <br /> field note sheets for the types of material encountered for the sod <br /> profiles and the percolation tests holes. <br /> Regomnnendatiots: <br /> In as much as the Percolation Test Results of the shallow tests <br /> varied considerably and not knowing at this time where the <br /> homesites are to be constructed, shallow septic systems are not <br /> recommended <br /> Due to the high water table it is recommended that a duel <br /> system consisting of leach lines, sumps and an alternating <br /> distribution box be constructed for each lot. <br /> EnMureer•s Sta g—amt <br /> Septic Systems can be installed to the density proposed and are <br /> n(A expected to cause health problems. <br /> Dwain C. Tosch <br /> ,1�chmetnts; <br /> Detail Map <br /> Percolation Field note sheAs (7) <br /> S - H 94 AS 1'Ett owR dopV4?II4TI" AR Tosr, H /4o1NO wRz:r<- 7'He CcMkR er,o� <br /> /UbuV7'u�fi.v� t,o )" TrS P0r.6 4v'> rT +5 eoRRacr <br />