My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011811 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DURHAM FERRY
>
207
>
2600 - Land Use Program
>
PA-1800128
>
SU0011811 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:28 AM
Creation date
9/4/2019 5:39:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0011811
PE
2622
FACILITY_NAME
PA-1800128
STREET_NUMBER
207
Direction
E
STREET_NAME
DURHAM FERRY
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
25527007
ENTERED_DATE
6/5/2018 12:00:00 AM
SITE_LOCATION
207 E DURHAM FERRY RD
RECEIVED_DATE
6/4/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DURHAM FERRY\207\PA-1800128\SU0011811\SS STUDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the holes were refilled with water <br /> to a level of six inches or more above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test forms are included in Appendix 3 of this report. The <br /> forms were signed by Mr. Wong or Ms. Beniamine and indicate the percolation rate for <br /> each hole based on the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than 1 min/in but less than or equal to 60 minutes per <br /> inch (min/in) drop. For the Site to utilize a standard septic system, one percolation test <br /> must demonstrate a satisfactory percolation rate within the proposed septic system <br /> disposal field. <br /> Details and results of the percolation tests are summarized in the following table. <br /> LOGE 1811 Page 7 <br />