Laserfiche WebLink
WAREHOUSE COMMERCIAL/INDUSTRIAL <br /> /0000fARKING AREA SHOULD ALLOW FOR VISUAL OBSERVATION BY <br /> OFFICE STAFF OR OTHER EMPLOYEES. <br /> REQUIRED PROJECT LIGHTING LEVELS AS FOLLOWS : <br /> ONE QUARTER ( 25/100) FOOTCANDLES OF ILLUMINATION PER <br /> /0SQUARE FOOT OF SURFACE IN PARKING AREAS. <br /> PERIMETER LIGHTING TO CREATE AN EVEN BAND OF LIGHT 25 'TO <br /> le000'050 ' WIDE ALONG THE ENTIRE PERIMETER OF THE PROJECT. <br /> �AUXILLARY LIGHTING OVER EACH POINT OF ENTRY. <br /> ALL LIGHTING FIXTURES TO BE OF VANDAL RESISTANT <br /> RESISTANT CONSTRUCTION. <br /> ALL LIGHTS SHOULD BE PLACED ON TIMERS CAPABLE OF TURNING <br /> LIGHTS ON AND OFF ONE-HALF HOUR PRIOR TO DAWN AND ONE <br /> -HALF HOUR PAST DUSK. <br /> CARE SHOULD BE GIVEN TO AVOID STRAY LIGHT FALLING ON <br /> ADJACENT PROPERTY. <br /> LANDSCAPING SHOULD INCLUDE SECURITY SHRUBBERY ALONG <br /> 000000 FENCES TO DISCOURAGE WOULD-BE INTRUDERS. <br /> SECURITY SHRUBBERY SHOULD ALSO BE USED UNDER WINDOWS. <br /> THE SITE PLAN DEPICTS NUMEROUS TREES AROUND THE PERIMETER <br /> AND INTERIOR OF THE COMPLEX. UNLESS TREES ARE OPTIMALLY <br /> PLACED AND KEPT TRIMMED UP ( SIX FEET ABOVE GROUND) , THEY <br /> CAN PROVIDE CONCEALMENT FOR CRIMINAL ACTIVITY, AS WELL <br /> AS OBSCURE OBSERVATION OF THE PROPERTY BY PATROL <br /> DEPUTIES. <br /> THE SITE PLAN DEPICTS EARTH BERMS. THESE SHOULD NOT <br /> EXCEED ONE AND ONE-HALF FEET IN HEIGHT, SO AS NOT TO <br /> OBSCURE OBSERVATION OF THE PROPERTY BY PATROL DEPUTIES. <br /> CCTV MONITORING SHOULD BE CONSIDERED FOR THE LOADING DOCK <br /> AREA. <br /> CONSTRUCTION SHOULD MEET THE CALIFORNIA MODEL BUILDING <br /> / AND SECURITY ORDINANCE AS DEVELOPED BY THE CALIFORNIA <br /> CRIME PREVENTION OFFICERS ASSOCIATION. <br />