My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008867 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ENTERPRISE
>
17864
>
2600 - Land Use Program
>
PA-1100135
>
SU0008867 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:43 AM
Creation date
9/4/2019 6:07:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0008867
PE
2632
FACILITY_NAME
PA-1100135
STREET_NUMBER
17864
Direction
S
STREET_NAME
ENTERPRISE
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
22919010
ENTERED_DATE
8/22/2011 12:00:00 AM
SITE_LOCATION
17864 S ENTERPRISE RD
RECEIVED_DATE
8/22/2011 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ENTERPRISE\17864\PA-1100135\SU0008867\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Tasiopoulos and indicates a percolation rate for the hole based on <br /> the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches, a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. A deep <br /> percolation test hole has a depth greater than 3.5 up to 25 feet; a satisfactory <br /> percolation rate for a deep test is 30 min/in or less. For the Site to utilize a standard <br /> septic system, one percolation test (either a shallow or deep test) must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field. <br /> Only a shallow percolation test was performed. Details and results of the percolation <br /> test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1, Satisfactory <br /> 8/31/2011 3.22 11.4 4 hr. perc. rate <br /> �- Shallow Test �' <br /> Note: A satgsfectory percolation rate fora "shallow"testi s than or equal to 60 minutes per inch. A satisfactory <br /> percolati to for a "deep"test is less than or equal to 30 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the sewage disposal areas of the Site have demonstrated a satisfactory <br /> percolation rate for the use of a standard septic system in accor nce with the <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizirfg leach line d seepage pitl should follow the San <br /> Joaquin County On-Site Wastewater Disposa�FS )-where applicable. - - <br /> LOGE 1123 Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.