CONCLUSIONS AND RECOMMENDATIONS <br /> In summary, the soil conditions in the percolation test locations appear to be suitable for <br /> use with on-site septic systems. Satisfactory soil percolation rates of 4.2 min/in (Parcel <br /> 1), 5.2 min/in (Parcel 2), 5.2 min/in (Parcel 3), and 25 min/in (Parcel 4) were observed in <br /> the test locations. <br /> The depth of ground water based on recent aquifer levels is estimated to range between <br /> 95 to 115 feet below ground surface. The ground-water Flow is to the northwest at a <br /> rate of approximately 14 to 17 feet per mile <br /> A water sample was collected from the domestic water well. Nitrate was detected in the <br /> sample at a concentration of 4.1 mg/L-N, well below the MCL of 10 mg/L-N. DBCP was <br /> not detected in the sample. <br /> We believe the Site suitable for the use of standard septic systems utilizing leach lines <br /> and seepage pits. No new construction is anticipated. <br /> • <br /> LOGE 1834 Page 9 <br />