Laserfiche WebLink
F J <br /> 3.2 Description of All Past On-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified at the Project Site: Past on-site potentials for <br /> contamination are low. The property has been used for agricultural purposes for more than <br /> 10 years. Historically there have been no underground storage tanks. The owner has no <br /> knowledge of above or below ground surfaces of contamination on the subject parcel. <br /> 1.. <br /> E A search for Use Reports and Permits did not yield any concerns for sources of contamination. <br /> � (See Appendix). All pesticides and fertilizers applied were done under Permit No. 39-02-3908000. <br /> F1l (See Appendix). At the south end of subject parcel is the Stockton East Water District Canal. <br /> E <br /> 3.3 Description of All Current On-Site Potential and/or Known Above and Below <br /> FR Ground Sources of Contamination Identified at the Project Site: Presently there are no <br /> underground storage tanks on the property and visual inspection did not produce any evidence <br /> E of buried containers, as well as no odors that would be associated with buried chemical tanks. <br /> F] There are no storage tanks above ground. There are no above ground fuel tanks on the site. <br /> On-site storm water is contained on site and dissipates through either percolation or <br /> evaporation. As previously stated, the Stockton East Water District Canal is located on subject <br /> parcel. <br /> 3.4 Description of All Past Off-Site Potential and/or Known Above and Below Ground <br /> Sources of Contamination Identified in the Area of the Project. Site: Past off-site potential <br /> for contamination is low. The subject parcel is located in agricultural community. <br /> 3.5 Description of all Present Off-Site Potential and/or Known Above and Below <br /> Ground Sources of Contamination Identified in the Area of the Project Site: Present <br /> F" off-site potential for contamination is low. There is no knowledge of below ground sources of <br /> contamination in the area of the project site that has or may impact the project site. <br /> Fill 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> P RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of Each Potential andlor Known Source of Contamination Identified for <br /> any Real and/or Potential Threat to Human Health and the Environment: The depth to <br /> ground water in this area is approximately 140 feet. Due to this depth, any pesticides, <br /> insecticides, and fertilizers used on the property in the past or present would have a minimal <br /> ' impact to the ground water. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the Above Evaluation: There are no chemical containers for fuel storage <br /> tanks on this site; thus, the potential for contamination is low. As previously stated, any <br /> pesticides, insecticides, and fertilizers used on the site do not pose any significant potential for <br /> F! contamination to the project site, and no mitigation measures are recommended. <br /> 2 <br /> Fi <br /> a <br />