My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003425
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
16750
>
2600 - Land Use Program
>
PA-0400180
>
SU0003425
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:24:08 AM
Creation date
9/4/2019 6:16:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0003425
PE
2626
FACILITY_NAME
PA-0400180
STREET_NUMBER
16750
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
APN
01918035
ENTERED_DATE
4/16/2004 12:00:00 AM
SITE_LOCATION
16750 E HWY 88
RECEIVED_DATE
4/13/2004 12:00:00 AM
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\16750\PA-0400180\SU0003425\PUB REC REL APPL.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
179454 <br /> REVISIONS BY <br /> PLUMBING NOTES: <br /> \ L r <br /> 1. SCOPE: <br /> A complete Plumbing System as generally delineated on the drawings, <br /> including service piping and final connections to equipment furnished an-'a <br /> installed by other trades as may be shown on ti-,e Archi tectual . Structi}r�,�.:,; <br /> Electrical or other Drawings of the contract documents. <br /> 2. CODES: <br /> All work materials and equipment shall be furnished and Installed. in n� s4.. v <br /> compliance with the following codes as adopted and amended by the a, G <br /> inspecting authority having ,jurisdiction. Nothing in these plans is to he <br /> construed to permit the Installation of work, material or equipment not <br /> conforming to these or other codes applicable to this project: <br /> A. 1997 UBC and 2001 CALIFORNIA AMENDMENTS NB �\ <br /> B. 2000 UPC and 2001 CALIFORNIA AMENDMENTS \ <br /> C. 2000 UMC and 2001 CALIFORNIA AMENDMENTS H5 <br /> 0. 1999 NEC and 2001 CALIFORNIA AMENDMENTS \� <br /> E. 1997 UFC and 1998 CALIFORNIA AMENDMENTS <br /> F. NATIONAL FIRE PROTECTION ASSOCIATION, 1996 EDITION <br /> G. TITLE 19, CALIFORNIA CODE OF REGULATIONS <br /> 3/,11 �p. Ct" <br /> 3. WORKMANSHIP: <br /> All work shall be done in a neat and workmanlike manner according to the <br /> best trade practice by those skilled in the particular trade. Equipment, <br /> fixtures, piping, etc. . shall be plumb, level , square or centered, e.tc. <br /> Equ I pmen t sha 11 be i ns to 11 ed I n s tr I c t comp 1 I ance w I th manuf'a.c tures'' EXP. 6-3Q--o6 <br /> .S : NO, 32936 <br /> recommendations. y11 <br /> � � <br /> 4. EXISTING INFORMATION: �F OIV}�- <br /> Location, size, elevation, materials, etc. , of extsting utilities Is <br /> provided from sources deemed reliable but is not guaranteed. Contractor F <br /> shall field verify all data BEFORE Proceeding ulth any work. No extra <br /> cost will be allowed for services not as shown. <br /> 5. PERMITS AND UTILITY SERVICE FEES: 40 Z <br /> Contractor shall arrange and Pay for all permits, inspections and service.. ,-. <br /> charges required in the Installation of the work. Z W <br /> UcoC? <br /> 6. ACCURACY: U <br /> Plans are diagrammatic. Contractor shall confirm all dimensions arld W } <br /> location of all walls, Partitions, fixtures, etc. , a-:most design plans: : ILW <br /> fcr consistency c+nd accuracy Prior to Commencing wor'I'. <br /> Q <br /> W <br /> 7. CALIFORNIA CODE OF REGULATIONS: W � <br /> 8 <br /> A. All hot water and hot water return lines shall be insulated in <br /> accordance with Sec. 2-5312 Title 20, Part 2, Chapter 2-53. I 3 <br /> B. All plumbing fixtures & equipment used (e.g. shouerheads, lavatory N <br /> faucets, sink faucets and water heaters) shall have been certified to <br /> efficiency standards for such appliances. cc <br /> St4 U. <br /> ; 3 <br /> kYa <br /> ;l � cc <br /> 0 W <br /> w a <br /> PRECAST CONCRETE BOX NTH <br /> cc <br /> LED MARKED "WATER" <br /> FiNiSHED GRADE <br /> Lao. IZ <br /> Zo <br /> I WO <br /> 18" X 18" CONCRETE ALL I� <br /> o <br /> AROUND IN UNPAVED AREAS <br /> om�m Z <br /> N �F-U �jZ <br /> USE PIPE EXTENSION WHERE VALVE- W Z 3 Z M <br /> OCCURS BELOW BOX ? <br /> 4 t W <br /> SHUT-OFF VALVE IN BOX _� �' '� � � �o~ 00 <br /> Z_ o <br /> DETAIL <br /> l� WWo <br /> NO SCALE P1_005 � �1+ W <br /> 4J �j N W�y <br /> F W 8 <br /> o ; F-68F8m <br /> COMMERCIAL <br /> � q <br /> ABOVE OR BELOW <br /> GRADE HOLDING TANKS r.8 <br /> MODEL 650OLHT - 1650OLHT <br /> L ' <br /> ----------- ------------Y--0, ' <br /> } <br /> I O'l <br /> `11 <br /> I ; <br /> � � � L Q <br /> I <br /> --- ------- <br /> ------------ I SN U 1 <br /> J �— Z" . <br /> �--� 2" VMLVE IM MN'C., MY\ G <br /> R Elva vlEw PLAN VIIEW <br /> SES. MEWL l � now � Z <br /> OPTIONAL 24- DIA. t <br /> OPTIONAL 24DIA.- PVC RISER c \ - P I O 'd <br /> � l l <br /> OPTIONAL 24' DIA. RING AND COVER y V V <br /> 1 0 <br /> CONCRETE PTR FOR W Z 0 <br /> GRADE RINGS � ADA E AND COVER �+ <br /> PVC RISERS � Q <br /> 240 <br /> 24 10- AIR SPACE, yl J <br /> INVERT ,} <br /> INLET <br /> 7'-4' 'J/ U_ O m <br /> 4 DIA. SCH_ 40 PVC LIQUID 4 "Y 0 <br /> 8-7. INLET FITTINGS LEVEL V) <br /> (STANDARD) SLS SATE GE�IaQPMEN = Z <br /> t ph t� _ NEE �� I-A ZlRA1�1 1NSMLLD PE M NUE v Q r <br /> P LRNS LaY ❑T HSS 0000 <br /> —1 <br /> CS UJ <br /> ELEVATION Z <br /> uaulfl <br /> 1KAV9C)OOLST <br /> L CAPACITY D1>�t:NsiaN <br /> ER GALLONS L 0 <br /> OLST 6623 15-11' EJ,.1 <br /> 9096 21'-5 Z <Ul <br /> OLST 11559OLST 14042 32*--5"0LST 16515 37'-11' <br /> DESIGN LOAD: H-20 TRAFFIC. NOTE: NOT RECDMMENDED EOR POTABLE WATER. <br /> FOR COMPLETE DESIGN NO WARRANTIES EXPRESSED OR �MPOED <br /> AND PRODUCT INFORMATION FOR MERCHA TIO LITY E}R FITNES EOR ANY I�1s�DQ VRL- I�1��LA5T <br /> CONTACT SENSEN PRECAST. PARTICULAR PURPOSE. <br /> -' Y---- - 5 6AI,[_Uh1 �-ZLU1aCa TANS lT-� \l� l N TAN <br /> rrZZ- 17 S�Y_V ICS L 1 IIS —TO C-� �i' <br /> I/5/02 PRECANT. t <br /> KAVLHT.dwg 2 2 <br /> ®2002 denser Precost <br /> V ' <br /> Date ®GT Oq' <br /> Scale A5 N=-D <br /> - PLUMBING PLAN <br /> Drawn K. C�LL�1�15 <br /> P" �i'0Job 0 403 <br /> n�m �` Sheet <br /> R-T FE <br /> UWVJ P 1 <br /> Of Sheets <br />
The URL can be used to link to this page
Your browser does not support the video tag.