Laserfiche WebLink
ahenone/Chocoholics Preliminary Septic System <br /> f <br /> GreaseTrap Influent from floor/wash sinks <br /> 1200 Gal. <br /> 2 Comp. <br /> sn <br /> :2 Influent from restrooms <br /> Primary Tank <br /> c 2000 Gal. <br /> .k <br /> 1 Comp. <br /> lr <br /> i <br /> SecondaryTank] <br /> 1200 Gal. STEP system with dual pumps and BioTube Pump Vault <br /> 2 Comp. <br /> f <br /> Distribution <br /> Manual Distribution Valve Box/Flow Director <br /> t <br /> Observation Pon <br /> 171 <br /> CL <br /> w Infiltrator Chambers 1.0 inch I.D.Laterals with c <br /> U <br /> en <br /> Clean-outs at distal ends <br /> w � a <br /> 0 0 <br /> t <br /> �—]0`� �—12`—� f—l0`—♦ <br /> I Observation Port <br /> 5' 10` <br /> 40 Ft. 2-36"diameter,16 ft.Dee <br /> 1.25 inch I.D.manifold P <br /> Seepage Pits <br /> I <br /> 1800 Sq.Pt. <br /> Filter Bed Area <br /> CHAMBERS TANKS <br /> Infiltrator chamber specs: I - 1200 Grease Trap <br /> Standard Infiltrator Chamber SC: 34"x 75"x 12" 1 -2000 Gallon Single Compartment <br /> 3 chambers on either side of center manifold 1 - 1200 Gallon Dual Compartment <br /> Chamber Spacers: 6" Biotube Pump Vault,dual pump system with alarm <br /> Scarify soil/effluent interface All tanks manholed per EHD requirements <br /> Two observation ports <br /> 1.0 inch I.D. lateral piping <br /> Clean-outs at distal ends per EHD requirements <br /> SEE ATTACHED SPECIFICATION SHEETS <br /> FOR ADDITIONAL INFORMATION <br />