Laserfiche WebLink
s <br /> HVAC SIZING Page 15 HVAC <br /> Project Title. . - . W . Boyett Residence Date. . 03/20/02�10 :56 :40 <br /> Project Address . . . . . . ... 28850 N. State Hyw 88 ******* --------------------- <br /> Lodi, California *v6 . 00* <br /> Documentation Author. . . David J. Starck ******* Building Permit # <br /> SKW & Associates <br /> 2237 Scenic Drive Plan Check / Date <br /> Modesto, CA 95355 <br /> (209) 523-8323 Field Check/ Date <br />` Climate Zone. . . . . . . . . . . 12 <br /> --=------------------- <br /> Compliance-Method. . . . . . MICROPAS6�v6 . 00'for_2001-Standards Tby-Enercomp, -Inc . <br /> _-- <br /> MICROPAS6�v6 .00File--BOYETT �Wth-CTZ12S92T�Program-HVAC SIZINGY� <br /> User -MP <br /> # 0837 User-SKw & Associates Run-Boyett Residence <br /> -------------- <br /> GENERAL INFORMATION <br /> - <br /> Floor Area. . . . . . . . . . . . . . . . . 3385 sf <br /> Volume . . . . . . . . . . . . . . . . . . . . . 33124 cf <br /> Front Orientation. . . . . . . . . . Front Facing 270 deg (W) <br /> Sizing Location. . . . . . . . . . . . STOCKTON AP <br /> Latitude. . 37 . 9 degrees <br /> Winter Outside Design. . . . . . <br /> 28 F <br /> Winter Inside Design. . . . . . . 70 F <br /> Summer Outside Design. . . . . . 98 F <br /> Summer Inside Design. . . . . . . 78 F <br /> Summer Range . . . . . . . . . . . . . . . 35 F <br /> Interior Shading Used. . . . . . Yes <br /> Exterior Shading Used. . . . . . No <br /> Overhang Shading Used. . . . . . Yes <br /> Latent Load Fraction. . . . . . . 0 .20 <br /> HEATING AND COOLING LOAD SUMMARY <br /> -------------------------------- <br /> Heating Cooling <br /> Description (Btuh) (Btuh) <br /> ---- ----------- -- -------- <br /> Opaque Conduction and Solar. . . . . . 24587 7108 <br /> Glazing Conduction. . . . . . . . . . . . . . . 9526 4536 <br /> Glazing Solar. . . . . . . . . . . . . . . . . . . . n/a 9161 <br /> Infiltration. . . . . . . . . . . . . . . . . . . . . 20234 5306 <br /> Internal Gain. . . . . . . . . . . . . . . . . . . . n/a 2100 <br /> Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5435 2821 <br /> Sensible Load. . . . . . . . . . . . . . . . . . . . 59781 31032 <br /> Latent Load. . . . . . . . . . . . . . . . . . . . . . n/a 6206 <br /> Minimum Total Load 59781 37239 <br /> Note: The loads shown are only one of the criteria affecting the selection <br /> of HVAC equipment . . Other relevant design factors such as air flow <br /> requirements, outside air, outdoor design temperatures, coil sizing, <br /> availability of equipment, oversizing safety margin, etc . , must also be <br /> considered. It is the HVAC designer' s responsibility to consider all <br /> .• 7r�efers wla�e., 3'el«tirtf �'�e.. /f(/�fG C�u�rvrtn7`-'. <br />