My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009506 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRAZIER
>
17601
>
2600 - Land Use Program
>
PA-1300015
>
SU0009506 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:34:04 AM
Creation date
9/4/2019 6:38:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0009506
PE
2622
FACILITY_NAME
PA-1300015
STREET_NUMBER
17601
Direction
E
STREET_NAME
FRAZIER
STREET_TYPE
RD
City
LINDEN
APN
06511006 07 08 09
ENTERED_DATE
2/5/2013 12:00:00 AM
SITE_LOCATION
17601 E FRAZIER RD
RECEIVED_DATE
2/5/2013 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRAZIER\17601\PA-1300015\SU0009506\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S = Sufficient <br /> I = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> �] ❑ 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> sl4�..�,_€�.� <br /> F-16.2 The minimum numler of llow and deep percolation tests was performed for each parcel. <br /> ® ❑ 6.3 Description of the date,time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> f�I preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> �.y ❑ 6.4 Description of the da?e, time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) <br /> ® ❑ 6.5 The test conformed)to SJC Policy EHD 02-02(correct depth,diameter, 2"gravel, 6"water refill, correct readings <br /> recorded). 3 <br /> ❑ 6.6 Complete Percolation Test Form (including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> F-16.7 Discussion of any potential`prdble"pre icted and/or the need for an engineered or alternative septic system. <br /> ❑ 6.8 Discussion of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> 5 <br /> Reviewed By: 44 — Reviewed Date: <br /> o <br /> FHD 26-02-003 Page 2 of 3 Sail Suitability Checklist <br />
The URL can be used to link to this page
Your browser does not support the video tag.