Laserfiche WebLink
S = Sufficient <br /> I = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ® ❑ 6.1 Site map showing khe location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> Q ❑ 6.2 The minim3uuum Aumbl�F of shallow and deep percolation tests was performed for each parcel. <br /> ❑ 6.3 Description of the date,time and protocol used to prepare the test hole,including depth and dimensions of hole, <br /> preparation of hole,and depth of water used to presoak(minimum 12 inches). <br /> ❑ 6.4 Description of the date,time and condition of the test hale after the 24-hour soak period(hole still intact,hole dry, <br /> jdepth to water remaining in hole,etc.) <br /> ❑ 6.5 The test conformed to SJC Policy EHD 02-02(correct depth,diameter, 2"gravel,6'water refill,correct readings <br /> recorded). 3 A <br /> i <br /> ❑ 6.6 Complete PercolatiZn Test Form(including readings)was provided with REHS verification signature. The rate <br /> was correctly calculateck using the last reading. <br /> 3 <br /> ❑ 6.7 Discussion of any patent I problems predicted and/or the need for an engineered or alternative septic system. <br /> ❑ 6.8 Discussed of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> I <br /> ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: Reviewed Date: <br /> i <br /> i <br /> I <br /> EHD 26-02-403 Page 2 of 3 Soil Suitability Checklist ] <br /> �Il A I'l(If19 I <br />