My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0000787 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
6106
>
2600 - Land Use Program
>
MS-93-113
>
SU0000787 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:28:04 AM
Creation date
9/4/2019 6:43:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0000787
PE
2622
FACILITY_NAME
MS-93-113
STREET_NUMBER
6106
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
MANTECA
Zip
95336
ENTERED_DATE
10/4/2001 12:00:00 AM
SITE_LOCATION
6106 E FRENCH CAMP RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRENCH CAMP\6106\MS-93-113\SU0000787\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*r �qw <br /> SOIL PROFILE <br /> A SOIL PROFILE WAS PERFORMED AT THE PROJECT SITE FOR EACH FOOT <br /> BELOW THE GROUND SURFACE FOR A DEPTH OF 8 FEET. THE SOIL WAS <br /> UNIFORM THROUGHOUT THE TEST BORING CONSISTING OF SANDY SOIL. <br /> PERCOLATION TEST RESULTS: <br /> ON MAY 4, 1994, PARCELS 1 AND 2 WERE TESTED TO DETERMINE THE <br /> PERCOLATION RATE. PARCELS 1 AND 2 PASSED THE PERCOLATION TEST WITH <br /> A PERCOLATION RATE OF 12 MIN/INCH FOR A DEPTH OF 3 FEET AND 6 MIN/ <br /> INCH FOR A DEPTH OF 3 FEET, RESPECTIVELY. PERCOLATION TESTS WERE <br /> CONDUCTED IN ACCORDANCE WITH SAN JOAQUIN COUNTY ENVIRONMENTAL <br /> HEALTH DEPARTMENT PROCEDURES. <br /> COMMENTS REGARDING EXISTING SEPTIC SYSTEMS : <br /> BASED ON THE INFORMATION GIVEN ON SHEET 4, THE EXISTING SEPTIC <br /> SYSTEMS IN THE AREA ARE FUNCTIONING WITH NO PROBLEMS . THE EXISTING <br /> SEPTIC SYSTEMS ARE USING A SEPTIC TANK AND LEACH LINES DESIGNED TO <br /> HANDLE THE WASTE FLOWS FROM EACH SITE. PITS ARE NOT BEING USED <br /> BECAUSE THE PERCOLATION RATE IN THE LEACH FIELD STRATA IS <br /> EXCELLENT. <br /> ENGINEER ' S OPINION ON THE SOIL SUITABILITY: <br /> FROM THE RESULTS OBTAINED FROM THE PERCOLATION TESTS AND THE <br /> HISTORY FROM EXISTING PERMITS FOR THE REPAIR AND INSTALLATION OF <br /> PRIVATE DISPOSAL SYSTEMS, THE SEPTIC SYSTEMS FOR PARCELS 1 AND 2 <br /> SHOULD CONSIST OF 8,000 S . F. AND 6 , 000 S . F. LEACH FIELD AREAS, <br /> RESPECTIVELY, WITH THE APPROPRIATE SIZE SEPTIC TANK, LENGTH AND <br /> LOCATION OF THE LEACH LINES DESIGNED FOR THE SOIL CONDITIONS IN <br /> THE AREA, AND THE SIZE OF THE HOUSE OR FACILITY TO BE SERVED. <br /> SEEPAGE PITS ARE NOT REQUIRED. <br /> THE GROUNDWATER TABLE IS LOCATED APPROXIMATELY 40 FEET BELOW THE <br /> GROUND SURFACE. THE SEPTIC SYSTEM SHOULD NOT ADVERSELY AFFECT THE <br /> GROUND WATER TABLE. <br /> IT IS OUR PROFESSIONAL OPINION THAT THE FINDINGS INCLUDED IN THIS <br /> STUDY ARE A REPRESENTATIVE ASSESSMENT OF THE PROJECT AREA AT THE <br /> PRESENT TIME. THIS OPINION CANNOT CONSTITUTE A GUARANTEE OR <br /> WARRANTY, EITHER EXPRESSED OR IMPLIED. <br /> WATER TEST RESULTS <br /> ENCLOSED ON THE FOLLOWING PAGES IS THE TEST RESULTS FOR THE <br /> EXISTING , WELL BY FGL ENVIRONMENTAL. <br /> SHEET 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.