Laserfiche WebLink
p4UIN _ <br /> THOMAS R. FLINN P.O. BOX 1810-1810 E. HAZELTON AVENUE <br /> DIRECTOR STOCKTON,CALIFORNIA 95201 <br /> (209)468-3000 FAX(209)468-2999 <br /> www.co.san-joaquin.ca.us <br /> THOMAS M.GAU `a <br /> DEPUTY DIRECTOR <br /> MANUEL SOLORIO Wcwlemg for YOU �L <br /> DEPUTY DIRECTOR 11 <br /> STEVEN WINKLER f .J{1113 <br /> DEPUTY DIRECTOR March 12, 2003 MAR L00 <br /> 1 <br /> BENTON ANGOVE qq�FFppq t�`� <br /> BUSINESS ADIVIMSTRATOR EIYN1IROl1 MENT HEALTH <br /> PERW/SER\/ICES <br /> Mr. Mike Huggins <br /> Environmental Health Department <br /> 304 East Weber Avenue <br /> Stockton, California 95202 ' <br /> SUBJECT: PA-03-07 A LOT LINE ADJUSTMENT APPLICATION TO ADJUST <br /> THE PROPERTY LINES OF FOUR PARCELS TO BECOME THREE PARCELS <br /> Dear Mr. Huggins: <br /> The San Joaquin County Department of Public Works, Flood Control Division has reviewed the subject <br /> application to determine its flood zone designation. The Federal Emergency Management Agency's <br /> Flood Insurance Rate Map (FIRM) No. 060299 0515 A, dated May 15, 1980, indicates that all parcels <br /> in this Lot Line Adjustment project are located in Zone AO (depth of one foot). The FIRM defines <br /> Zone AO as areas of 100-year shallow flooding where depths are between one (1) and three (3) feet. <br /> New and substantially improved structures constructed in the 100-year flood areas shall meet the <br /> Federal Emergency Management Agency's regulations that are stipulated in the San Joaquin County <br /> Ordinance Code - Section 19605.12 (b) as follows: <br /> "All new construction and substantial improvement of any structure in FIRM Zone AH or AO shall <br /> have the lowest floor, including the basement, elevated at least one (1) foot higher than the depth <br /> number specified in feet on the Flood Insurance Rate Map or at least two (2) feet if no depth number <br /> specified..." <br /> Furthermore, the San Joaquin County Ordinance Code - Section 19605.18 states, "No fence without <br /> reasonable access openings at least twenty (20) feet in width shall be constructed nor shall any <br /> structure or a pole be erected within ten (10) feet of the landside or waterside levee toe or within <br /> twenty-five (25) feet of the top of either bank of any natural or manmade stream without obtaining <br /> the approval of the Department of Public Works." Y <br /> Should you have any questions regarding this letter, please contact me at 468-3062; <br /> 2Since ly, <br /> ARLES F. <br /> Senior Civil Engineer <br /> CFK:SS:to <br /> FC-38043-T1 <br /> Enclosure <br /> c: Mr. Monte K. Seibel <br /> 221 West Oak Street, Suite B-2 <br /> Lodi, California 95240 <br />