SU0011261
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
4 (STATE ROUTE 4)
>
6701
>
2600 - Land Use Program
>
PA-1700039
>
SU0011261
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:09:39 AM
Creation date
9/4/2019 6:46:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011261
PE
2631
FACILITY_NAME
PA-1700039
STREET_NUMBER
6701
Direction
E
STREET_NAME
STATE ROUTE 4
City
STOCKTON
Zip
95215-
APN
10306013
ENTERED_DATE
3/3/2017 12:00:00 AM
SITE_LOCATION
6701 E HWY 4
RECEIVED_DATE
3/3/2017 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\HWY 4\6701\PA-1700039\SU0011261\APPL.PDF \MIGRATIONS\F\HWY 4\6701\PA-1700039\SU0011261\CDD OK.PDF \MIGRATIONS\F\HWY 4\6701\PA-1700039\SU0011261\EHD COND.PDF \MIGRATIONS\F\HWY 4\6701\PA-1700039\SU0011261\EHD PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1) Driveway and maneuvering areas shall be paved and permanently maintained to provide a <br /> durable dust free surface. All other areas that are used for vehicular traffic shall be surfaced and <br /> permanently maintained with a chip seal. Trailer parking areas shall be surfaced with a <br /> minimum four inches of aggregate base. (Development Title Section 9-1015.5[e][21a.) <br /> j. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC)and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project. The following conditions <br /> shall be addressed prior to submittal of a building permit application to the Building Inspection <br /> Division: <br /> (1) A building permit for each separate structure or building is required. Submit plans, Specifications <br /> and supporting calculations, prepared by a Registered Design Professional (architect or <br /> engineer) for each structure or building, showing compliance with The 2016 California Building, <br /> Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes as may be <br /> applicable. Plans for the different buildings or structures may be combined into a single set of <br /> construction documents. <br /> (2) The required plans must be complete at the time of submittal for a building permit. Plans <br /> must address building design and construction,fire and life safety requirements, accessibility <br /> and show compliance with the current Cafrfornia codes and San Joaquin <br /> County ordinances. A complete set of plans must include fire sprinkler plans(if required), truss <br /> design submittals, metal building shop drawings, structural plans and calculations, plumbing, <br /> electrical and mechanical drawings and energy report. <br /> (3) A soils report is required pursuant to CBC § 1803 for foundations. All recommendations of the <br /> Soils Report shall be incorporated into the construction drawings. <br /> (4) For each proposed new building, provide the following information on the plans: <br /> a. Description of proposed use <br /> b. Existing and proposed occupancy Groups <br /> c.Type of construction <br /> d. Sprinklers(Yes or No) <br /> e. Number of stories <br /> f. Building height <br /> g.Allowable floor area <br /> h. Proposed floor area <br /> i. Occupant load based on the CBC <br /> j. Occupant load based on the CPC <br /> (5) If high piled combustible storage is to be used in a building, an automatic fire sprinkler <br /> system will be required. <br /> (6) Accessible routes shall be provided per CBC§ 11 B-206. At least one accessible <br /> route shall be provided within the site from accessible parking spaces to the accessible building <br /> or facility entrance they serve. Where more than one route is provided, all routes must be <br /> accessible. §11B-206.2.1 <br /> (7) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project. These parking space(s) shall be located as close as possible to <br /> the primary entrance to the building. <br /> (8) Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 of <br /> the California Plumbing Code <br /> PA-1700039 Condition of Approval 4 <br />