Laserfiche WebLink
• 8.0 IDENTIFIED CONTAMINATION SOURCES <br /> The following sources of past, current, on-site, and off-site contamination have <br /> been identified as a result of this investigation: <br /> Identified Contamination Source Evaluation <br /> 1. Two rows of trees were located on The typical standard of care for <br /> the Site from 1937 until the 1960s SSCRs does not require any further <br /> or 1970s. The southern portion of investigation of former agricultural <br /> the Site was open land that may use. <br /> have been used for small-scale <br /> agriculture or pasture. (Past on- <br /> site) <br /> 2. Two structures were located on the The typical standard of care for <br /> Site from 1937 or earlier until at SSCRs does not require any further <br /> least the 1960s. They were investigation of former structures. <br /> removed before Ms. Chand <br /> acquired the Site. For any former <br /> structure dating from the 1980s or <br /> earlier, the assumption is made <br /> • that lead-containing materials <br /> and/or pesticide residues may be <br /> present in and around the footprint <br /> of the former structure. It is <br /> possible that underground <br /> infrastructure from the original <br /> buildings could also remain on the <br /> Site. (Past on-site) <br /> 3. Four listed facilities were identified Based on their distances from the <br /> within one-quarter mile of the Site, the types and status of the <br /> subject Site. (Current and past off- databases on which they are listed, <br /> site) and information on file at the San <br /> Joaquin County Environmental <br /> Health Department, these facilities <br /> are not anticipated to have impacted <br /> the subject Site. <br /> • <br /> LOGE 1838 7 <br />