Laserfiche WebLink
/3.3 Description of all current on-site potential and/or known above and below ground <br /> sources of contamination identified at the project site: Presently, there are no underground <br /> storage tanks on the property and visual inspection did not produce any evidence of buried <br /> containers, as well as no odors that would be associated with buried chemical tanks. There are no <br /> above ground storage tanks on site as well. There are no above ground fuel tanks on the site. <br /> There is a drainage ditch along the perimeter of the property near the adjacent streets. <br /> /3.4 Description of all past off-site potential and/or known above and below ground sources <br /> of contamination identified in the area of the project site: Past off-site potential for <br /> contamination is the adjacent trucking facility. Other sources of potential contamination is the <br /> surrounding vineyards and the chemicals used in their farming operation. There is no knowledge <br /> of below ground sources of contamination in the area of the project site that has or may impact <br /> the project site. <br /> 13.5 Description of all past off-site potential and/or known above and below ground sources <br /> of contamination identified in the area of the project site: Present off-site potential for <br /> contamination is the adjacent trucking facility. Other sources of potential contamination are the <br /> surrounding vineyards and the chemicals used in their farming operation. There is no knowledge <br /> of below ground sources of contamination in the area of the project site that has or may impact the <br /> project site. <br /> 4.0 EVALUATION OF PAST AND CURRENT SOURCES OF <br /> CONTAMINATION IDENTIFIED AT OR NEAR THE SITE AND <br /> RECOMMENDATIONS FOR FURTHER ACTION: <br /> 4.1 Evaluation of each potential and/or known source of contamination identified for any <br /> real and/or potential threat to human health and the environment: The depth to ground water <br /> in this area is approximately 110 feet. Due to this depth, any pesticides, insecticides, and <br /> fertilizers used on the property in the past or present would have a minimal impact to the ground <br /> water. the use of approved best management practices for the containment of soil or any <br /> contaminates by straw waddles around the construction site and other practices to reduce the <br /> introduction of any dirt or contaminates into the storm runoff system will be required at the time <br /> of any future construction per County Building Department. The adjacent truck facility is also a <br /> potential for contamination due to the materials used to maintain these vehicles. This particular <br /> facility does not carry hazardous materials eliminating potential high risk contamination. <br /> 5.0 CONCLUSIONS AND RECOMMENDATIONS SECTION: <br /> 5.1 Discussion of the above evaluation: The aforementioned trucking facility creates the <br /> greatest potential for contamination. However, with safe material management practices in use, <br /> the potential for contamination should be at a minimum. <br /> 5.2 The Report is inclusive: All information in this report does not reference any other <br /> documents that are not contained in this report. <br /> 5.3 Report was signed, dated, and stamped: See below. <br /> 2 <br /> CA031 11\Surface and Subsurface Report 0504 <br />