My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012279
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10500
>
2600 - Land Use Program
>
PA-1900025
>
SU0012279
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2021 9:22:19 AM
Creation date
9/5/2019 10:57:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012279
PE
2631
FACILITY_NAME
PA-1900025
STREET_NUMBER
10500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-
APN
19327019
ENTERED_DATE
4/17/2019 12:00:00 AM
SITE_LOCATION
10500 S HARLAN RD
RECEIVED_DATE
4/16/2019 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\tsok
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\10500\PA-1900025\SU0012279\APPL.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. Each parking stall shall be an unobstructed rectangle, minimum 9 feet wide and 20 feet long. <br /> (Development Title Section 9-1015.5[b]) <br /> 5. Each truck parking stall shall be an unobstructed rectangle, minimum 15 feet wide and 25 feet <br /> long. (Development Title Section 9-1015.6[c][1]). <br /> e. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> 1. Access driveways shall have a width of no less than 25 feet for two-way aisles and 16 feet for <br /> one-way aisles, except that in no case shall driveways designated as fire department access be <br /> less than 20 feet wide. (Development Title Section 9-1015.5[h][1]) <br /> 2. The design of the driveway and traffic circulation plan for the site shall be incorporated into the <br /> construction plans. <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> 1. If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> 2. Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that <br /> such light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][41) <br /> g. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> 1. A minimum 10 foot wide landscaped strip, respecting the ultimate right-of-way width of South <br /> Harlan Road, shall be installed across the frontage of the project site. (Development Title <br /> Section 9-1020.5[c]) <br /> 2. Areas of the property which are not a part of the project shall be barricaded from traffic and <br /> kept mowed and dust free. <br /> h. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be included <br /> on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from any future <br /> right-of-way line, including any corner cut-off(snipe). (Development Title Section 9-1710.2[g]) <br /> i. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division: <br /> 1. A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with the 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2. A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> PA-1900025 —Conditions of Approval 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.