SU0005843
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
16100
>
2600 - Land Use Program
>
PA-0300638
>
SU0005843
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:48 AM
Creation date
9/5/2019 10:59:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0005843
PE
2625
FACILITY_NAME
PA-0300638
STREET_NUMBER
16100
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06504033
ENTERED_DATE
12/28/2005 12:00:00 AM
SITE_LOCATION
16100 E HARNEY LN
RECEIVED_DATE
12/27/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARNEY\16100\PA-0300638\SU0005843\APPL.PDF \MIGRATIONS\H\HARNEY\16100\PA-0300638\SU0005843\EH COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f SIT PLAN CHECK'LIST- . . <br /> • Size: The Site Plan must be drawn on minimum 18"x 24"reproducible material. <br /> North An ow; Date'and;Scale: .Use.an engineer's scale-(i.e:, 1"to Mor 1"t6'40',preferred) The-.d ire''ctio'n'.of <br /> north should be eQintmg:towards=the fop of the,page - <br /> Streets and Easerherits: .Location and names'of all,streets and easements'bordering on.the property WO. <br /> -access.detail's: <br /> Properly Unes All property lines or boundary,lines of the parcel with dimensions <br /> Vicirnty Map::A vrcinitymap'showing-the,location of the property in relation to surrounding streets <br /> Existing an Rio osed Develo menta All,exis <br /> • p p ting structue6s (labeied.'existing')and any proposed structures <br /> (l abeled'proposed').ivith dimensions-square footage and distances from other structures and proper(y-Aines., <br /> Any existing structures plannedfor.remova1 sh6; d.be shown with dashed lines. The use'and'numbero#floors <br /> should.be labeled-on each structure: <br /> • Parking and Driveways: The location, dimensions and surface niaterial.of all existing and proposed parking and <br /> driveways. Calculations indicating the number of required spaces must be shown. (Refer to'County Parking <br /> Lot Standards')_ <br /> • Water Wells: The.location of existing and proposed water wells on-site and any off-site wells within 150'of the <br /> proposed development. Wells must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; <br /> - 300'from leach lines; <br /> I� '150'from sumps or seepage pits; and <br /> I - 10'from property lines. <br /> If public water will be utilized, a'will-serve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet, public sewer hook-up, or existing and proposed <br /> sewage disposal systems and any off-site sewage disposal systems within 150'of the property_ <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines,structures,driveways and swimming pools; <br /> - 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> - 10'from structures, driveways and swimming pools; <br /> - 100'from wells, streams and waterways. <br /> - 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining properties <br /> (this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized, a"will-serve"letter must be submitted from the service provider. <br /> • Storm Drainage: The location of existing and proposed storm drainage facilities (check with Engineering staff <br /> regarding design criteria). If subject to flooding,the 100-year flood elevations must be shown. Indicate any <br /> unusual topographic features of the site(e.g.steep slopes, or drainage courses). Grading and contours need to <br /> be shown. <br /> • Landscaping: The location of existing and proposed landscaping and trees 6"or greater in diameter(note any <br /> trees to be removed). Calculation indicating the percentage of the net site area to be landscaped must be <br /> shown. (Refer to County Landscaping Standards). <br /> Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs <br /> and fences and the location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> SITE-PiANS MUST BE`GOMPLETE AND LEGIBLE <br /> • Before applying, check your Site Plan to make sure that it contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review your draft Site Plan prior to having copies run. <br /> • Faint prints and light blue lines will not be accepted because they cannot be reproduced or microfilmed. <br /> F:IDEVSVCIPIanningApplication FormsWse Permit(Revised 1-2-03) Page 8 of 9 <br />