My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008577
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HENDERSON
>
18500
>
2600 - Land Use Program
>
PA-1000267
>
SU0008577
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:34 AM
Creation date
9/5/2019 11:09:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0008577
PE
2611
FACILITY_NAME
PA-1000267
STREET_NUMBER
18500
Direction
S
STREET_NAME
HENDERSON
STREET_TYPE
RD
City
TRACY
APN
20917003
ENTERED_DATE
1/7/2011 12:00:00 AM
SITE_LOCATION
18500 S HENDERSON RD
RECEIVED_DATE
1/7/2011 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HENDERSON\18500\PA-1000267\SU0008577\APPL.PDF \MIGRATIONS\H\HENDERSON\18500\PA-1000267\SU0008577\CDD OK.PDF \MIGRATIONS\H\HENDERSON\18500\PA-1000267\SU0008577\EH COND.PDF \MIGRATIONS\H\HENDERSON\18500\PA-1000267\SU0008577\EH PERM.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1227
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Greenhouse Gas Emissions Technical Report <br /> Mountain House Neighborhoods K& L, San Joaquin County, California <br /> . <br /> The resultant Project and Baseline residential energy GHG emissions are shown in Table 1 with <br /> supporting information provided in Appendix A, Section 5. <br /> 3.3.3 Non-Residential Buildings Energy Use <br /> To estimate GHG emissions for the Project, ENVIRON used CalEEMod, which relies upon the <br /> most recent Commercial End Use Survey (CEUS) conducted by the California Energy <br /> Commission (CEC).28 Project emissions have been calculated using a MID emission factor that <br /> accounts for the 20% RPS required by 2010, as discussed earlier. <br /> ENVIRON understands-that SJVAPCD is still in the process of developing baseline GHG <br /> metrics for commercial projects. In the absence of reliable baseline commercial GHG metrics <br /> from SJVAPCD, ENVIRON applied the same percentage reduction to the non-residential <br /> Baseline energy usage as was estimated for the residential energy usage using SJVAPCD <br /> baseline energy metrics.29 Based upon the Project's residential GHG savings over the <br /> Baseline, ENVIRON estimated a reduction of emissions of approximately 53% for natural gas: <br /> and 30% for electricity for non-residential energy use compared to Baseline. <br /> The resultant Project and Baseline GHG emissions associated with non-residential energy <br /> usage are shown in Table 1 with supporting information in Table 2 and Appendix A, Section 5. <br /> 3.3.4 Recreational Facilities Energy Use <br /> Recreational facilities at the Project will include a 3,750 square foot outdoor swimming pool. <br /> To estimate the energy usage with the swimming pool, ENVIRON obtained average energy <br /> consumption of filter pumps and water heaters from a study conducted in Oakland, California;) <br /> and then scaled the energy consumption to reflect the pool size at the Project. The energy <br /> usage was also scaled to account for the higher average ambient temperature in Tracy <br /> compared to the study area and an assumed greater efficiency of new pool heaters. Shea <br /> Homes has committed to heat the pool using solar heating; thus, for the Project scenario, <br /> natural gas usage is replaced by solar heating. <br /> The resultant Project and Baseline pool energy GHG emissions are shown in Table 1 with <br /> supporting calculations and references in Tables f, 7, and B. <br /> 3.3.5 Water Supply, Treatment and Distribution <br /> This section describes the calculation of indirect emissions from the production of electricity to <br /> convey, treat and distribute water and wastewater. The amount of electricity required to treat <br /> and supply water depends on the volume of water involved as well as the sources of the water. <br /> 28 <br /> California Energy Commission.2006. California Commercial End-Use Survey. Prepared by Kema Inc. Available at: <br /> http://www.energy.ca.gov/ceus/ G <br /> zs The percentage reduction between Baseline and Project residential energy usage was decreased slightly to <br /> conservatively remove any credit obtained from installing EnergyStar appliances, which may not be included in <br /> commercial spaces. i <br /> 03-25858A 12 EN V I R O 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.