set of plans must include fire sprinkler plans, truss design submittals, metal building shop <br /> drawings, structural plans and calculations, plumbing, electrical and mechanical drawings and <br /> energy report. <br /> (4) A soils report is required pursuant to CBC§ 1803 for foundations and CBC appendix§J104 for <br /> grading. All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> (5) For each proposed new building, provide the following information on the plans: <br /> a. Description of proposed use <br /> b. Existing and proposed occupancy Groups <br /> c. Type of construction <br /> d. Sprinklers(Yes or No) <br /> e. Number of stories <br /> f. Building height <br /> g. Allowable floor area <br /> h. Proposed floor area <br /> L Occupant load based on the CBC <br /> j. Occupant load based on the CPC <br /> (6) The building shall be provided with an automatic fire sprinkler system or separated into <br /> conforming fire areas. <br /> (7) If high piled combustible storage is to be used in a building,an automatic fire sprinkler system will <br /> be required. <br /> (8) Accessible routes shall be provided per CBC § 11 B-206. At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading zones; <br /> public streets and sidewalks; and public transportation stops to the accessible building or facility <br /> entrance they serve.Where more than one route is provided,all routes must be accessible.§116- <br /> 206.2.1 <br /> (9) At least one accessible route shall connect accessible buildings, accessible facilities, accessible <br /> elements and accessible spaces that are on the same site. §11 B-206.2.2 <br /> (10) At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility, including mezzanines, which are <br /> otherwise connected by a circulation path. §11 B-206.2.4 <br /> (11) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project These parking space(s)shall be located as close as possible to the <br /> primary entrance to the building. <br /> (12) Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 of <br /> the California Plumbing Code. <br /> (13) Pursuant to Section 422.4 of the California Plumbing Code, toilet facilities shall be accessible to <br /> employees at all times, should not be more than 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> (14) This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> requirements of the California Code of Regulations, Title 22, Division 2, Chapter 2.7. <br />