Laserfiche WebLink
1117 Lone Palm Avenue, Suite B <br /> C' VATC, <br /> Modesto, CA 95351 <br /> � (��} '� http://www.atcassociates.com <br /> l`J h, 209.579.2221 <br /> Fax 209.579.2225 <br /> ASSOCIATES INC . JINN 3 112305 <br /> June 27, 2005 EMAROW04T HCES 1 <br /> 54.14885.0001 pE?,M1T <br /> Ms. Margaret Lagorio <br /> San Joaquin County Environmental Health Department <br /> 304 E. Weber Street, Third Floor <br /> Stockton, California 95202 <br /> Subject: Addendum to Workplan for Additional Subsurface Investigation for 6732 East Highway <br /> 88, Stockton, California <br /> Dear Ms. Lagorio: <br /> ATC Associates Inc. has prepared this letter to serve as an addendum to ATC's May 2, 2005 Additional <br /> Workplan for Subsurface Investigation prepared on behalf of Ms. Lolly Bozzano for the performance of a <br /> subsurface investigation at the above referenced site(Figure 1). <br /> This addendum has been prepared based on June 1, 2005 correspondence from Ms. Margaret Lagorio of <br /> San Joaquin County Environmental Health Department(SJCEHD). <br /> Construction of Monitor and Vapor Wells <br /> To determine the lateral and vertical extent of soil and groundwater contamination at the site, and to <br /> evaluate the feasibility of vapor extraction as a remedial alternative for cleanup at the site, a total of two <br /> groundwater monitoring wells and three vapor extraction wells will be installed at the project site. <br /> The vapor extraction wells will be constructed of 2-inch diameter, schedule 40 PVC casing and 0.010" <br /> slot size screen (Figure 2). The bottom of the screen interval will be fitted with an end plug and the top of <br /> the casing will be fitted with an expandable, water-tight, locking cap. A well screen length in the vapor <br /> extraction wells will extend from a depth of 15 to 45 feet bgs. Above the screen will be a sand layer from <br /> 13 to 45 feet bgs, a bentonite layer from 10 to 13 feet bgs, and grout filling from 0 to 10 feet bgs. A <br /> traffic-rated well box will be installed flush with the surface. <br /> The groundwater monitoring wells will be installed downgradient from the former tank pit and will be <br /> utilized to monitor the downgradient concentrations of petroleum hydrocarbons in a lower water bearing <br /> zone. The wells will be constructed of 2-inch diameter schedule 40 PVC and will be completed to a depth <br /> of approximately 140 feet bgs (Figure 3). The groundwater wells will have 0.020" slot size screen from <br /> approximately 130 to 140 feet bgs inside of a conductor casing that will extend to a depth of 120 feet bgs. <br /> Based upon additional review of the logs from borings CPT] and CPT2, ATC is recommending a shorter <br /> screen length. Above the screen will be a sand layer from 125 to 140 feet bgs, a bentonite layer from 122 <br /> to 125 feet bgs, and grout filling from 0 to 122 feet bgs. A traffic-rated well box will be installed flush <br /> with the surface. <br /> All work will be performed in accordance with the methodologies and practices described in ATC's <br /> original workplan dated May 2, 2005. <br /> 1 <br /> ENVIRONMENTAL, GEOTECHNICAL AND MATERIALS PROFESSIONALS <br />