Laserfiche WebLink
c . The perimeter of the absorption bed may require a 2'' <br /> width redwood board retaining wall the height of the <br /> bed to maintain soil stability . <br /> 8 . 9 . 4 . Variation in design and sizing of a mound system must <br /> be done by a registered engineer and approved by the <br /> Director of Environmental Health . <br /> 8 . 10 . SUMPS (GREATER THAN EIGHT ( 8) FEET IN DEPTH) <br /> 1 . Sumps are to be dug no deeper than twenty-five ( 25) <br /> feet nor closer than ten ( 10) feet above the water <br /> table . <br /> - 2 . Sumps installed at depth four ( 4) feet to twenty-five <br /> (25) feet, shall reach a permeable soil strata . <br /> 9 . VAULTED PRIVIES <br /> 9 . 1 . General - A vaulted privy is a temporary means of <br /> disposal . For other than temporary use , it, will be <br /> permitted only in those areas where a subsurface <br /> disposal system is not. practicable . <br /> 9 . 2 . Location shall be such that it cannot, discharge , flow , <br /> seep or drain into any ground water or water intended <br /> for human or animal consumption . The following are <br /> minimum distances <br /> 9 . 2 . 1 . From any well 100 feet <br /> 9 . 2 . 2 . From any dwelling 50 feet <br /> 9 . 2 . 3 . From any property line 10 feet, <br /> 9 . 2 . 4 . From water table 5 feet, <br /> _ <br /> 9 . 3 <br /> 3 . Construction . <br /> 9 . 3 1 . The pit shall be constructed of concrete and be <br /> water tight and not less than three ( 3) feet long <br /> and thirty ( 30 ) inches wide and shall be at least <br /> five (5 ) feet. deep. For each additional seat , <br /> the length shall be increased by two ( 2) , feet . <br /> 9 . 3 2 . The building shall be of tight construction to <br /> exclude inflects and rodents . The riser shall be <br /> of matched tongue and groove lumber or concrete <br /> _ and molded seats shall be provided with tight. <br /> covers . The door shall be self-closing . The <br /> base shall be banked with earth and the vent pipe <br /> shall extend from the vault to one ( 1 ) foot above <br /> the roof . The top shall be screened with sixteen <br /> ( 16) mesh screen . <br /> 9 . 4 .D. A Sanitation Permit is required prior to construction . <br /> 2 C� <br />