My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004594 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
31555
>
2600 - Land Use Program
>
PA-0400417
>
SU0004594 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:30:56 AM
Creation date
9/6/2019 9:56:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004594
PE
2622
FACILITY_NAME
PA-0400417
STREET_NUMBER
31555
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
APN
25314004
ENTERED_DATE
8/6/2004 12:00:00 AM
SITE_LOCATION
31555 S MACARTHUR DR
RECEIVED_DATE
8/4/2004 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MACARTHUR\31555\PA-0400417\SU0004594\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Perc test locations were determined by pacing from roads or Parcel corners, which are readily <br /> marked with stakes. A measure wheel could not be used due to heavy vegetation. <br /> The following information describes the preparation of the percolation test borings and the actual <br /> percolation testing: On April 26, 2005, one shallow perc test boring and one deeper test boring <br /> were drilled on the proposed Parcels in the locations referenced on the Tentative Map found in <br /> Appendix C. The sidewalls of the shallow borings were scored with a pry-bar and the loose <br /> material removed. Two inches of fine gravel was placed at the bottom and three-inch perforated <br /> PVC pipe was inserted in all of the test borings. All test borings were pre-saturated with 12 inches <br /> of water, approximately 24 hours before the start of testing. <br /> On May 2, 2005, at 0900 hrs,percolation testing commenced for Parcels 10, 11, 7 and 6. There <br /> was standing water after the 24-hour soak period in three of the perc tests that failed, as depicted in <br /> Table 1 below. Consequently,EHD Perc Test Procedure#1 was conducted for these three borings. <br /> There was no standing water after the 24-hour soak period in the other test borings with passing <br /> rates. Therefore, Percolation EHD Test Procedure#2 was performed for these test borings. <br /> On May 3, 2005, at 0900 hrs,perc testing commenced for Parcels 1, 2, 3 and 9 under the <br /> procedures referenced above. On May 4, 2005, perc testing commenced at 0900 hrs for Parcels <br /> 8,4 and 5, also under the referenced procedures. The last half hour of the tests was witnessed by <br /> David Van Dyne of the San Joaquin County Environmental Health Department. <br /> The following Table summarizes and illustrates the pertinent data for each proposed Parcel, <br /> including potential septic system structures based on the depth of passing perc rates,proposed <br /> acreage,post soak period status and perc test results for the respective perc test depths: <br /> Page-4- <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.