My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
414
>
2200 - Hazardous Waste Program
>
PR0514402
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2019 11:23:32 AM
Creation date
9/6/2019 9:59:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514402
PE
2227
FACILITY_ID
FA0010746
FACILITY_NAME
JAAS AUTO SERVICE
STREET_NUMBER
414
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206-1707
APN
16503004
CURRENT_STATUS
01
SITE_LOCATION
414 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Large Quantity Hazardous Waste Generator Inspection,Report <br /> Facility Name: Facility Address: Date: <br /> JAAS AUTO SERVICE 414 W CHARTER WAY, STOCKTON September 24, 2014 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) _ <br /> Item# Remarks <br /> 403 Failed to keep hazardous waste containers closed except when adding or removing hazardous waste. Two 55 gallon <br /> steel drums of used oil, a black plastic garbage can of used oil, a 5 gallon blue plastic bucket of used oil, and a 5 gallon <br /> blue steel bucket of used oil were observed behind the shop open, without lids. The used oil tank was observed with an <br /> open bung hole; the bung could not be located at the time of inspection. Three 55 gallon steel drums of used oil were <br /> observed in the shop pit storage area without lids. All hazardous waste containers shall be closed at all times except <br /> when adding or removing waste. Immediately close these containers and ensure all hazardous waste containers are <br /> closed when not adding or removing waste. This is a Class II violation. <br /> 501 Failed to comply with new hazardous waste tank system assessment requirements. Facility does not have a tank <br /> assessment for the used oil tank. Mr. Bongcaron estimated the tank to be 200 gallons. The owner or operator of a <br /> hazardous waste tank shall obtain a written assessment reviewed and certified by an independent, qualified, <br /> professional engineer, registered in California attesting that the system has sufficient structural integrity, is acceptable <br /> for the transferring, storing, and treating of hazardous waste, and that the tanks and containment system are suitably <br /> designed. Immediately have an assessment prepared for the used oil tank. Submit a schedule showing when this will <br /> be accomplished to the EHD. This is a Class I violation. <br /> 506 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. Inspections of the <br /> hazardous waste tank system was not performed and documented. The following items are required to be inspected at <br /> least daily: <br /> 1. overfill/spill control equipment; <br /> 2. aboveground portions of the tank system to detect corrosion or releases of water; <br /> 3. data gathered from monitoring and leak-detection equipment; <br /> 4. outside areas of the tank system including secondary containment to detect erosion or signs of releases of <br /> hazardous waste; <br /> 5. for uncovered tanks, the level of waste in the tank. <br /> Immediately begin required inspections of the hazardous waste tank system, and document the items inspected. <br /> Submit a copy of the inspection log for the next 30 days to the EHD. This is a Class II violation. <br /> 605 Failed to completely label containers or tanks of hazardous waste. Two 55 gallon steel drums of used oil, a black plastic <br /> garbage can of used oil, a 5 gallon blue plastic bucket of used oil, and a 5 gallon blue steel bucket of used oil were <br /> observed behind the shop without labels. A 5 gallon blue plastic bucket of used oil was observed next to the used oil <br /> tank without a label. Three 55 gallon steel drums of used oil were observed in the shop pit storage area without labels. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words "Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties (ignitable, corrosive, reactive, toxic) <br /> -physical state (liquid, solid) <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all containers are marked with all the required information. Since it <br /> cannot be determined how long the unlabeled containers of used oil have been on site, immediately contact a licensed <br /> hazardous waste hauler to dispose of this waste under manifest and submit a copy of the manifest to the EHD. This is a <br /> Class II violation. <br /> Received by(initial): Inspector: Phone: Date: <br /> /e STACY RIVERA, Senior REHS (209)468-3440 09/24/2014 <br /> Page 6 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.