Laserfiche WebLink
California Regional Water Quality control Board <br /> `\' Central Valley Region °M <br /> Robert Schneider,Chair Arnold <br /> Dr.Alan LloydSchwarnenegger <br /> Secretaryfor Sacramento Main Office Governor <br /> Environmental 11020 Sun Center Drive#200,Rancho Cordova,California 95670-6114 <br /> Protection Phone(916)464-3291 •FAX(916)464-4775 (n^�{ <br /> http://www.wataboards.ca.gov/centralvalley ❑ Iu t(V(/EU <br /> Illl U <br /> 29 March 2005 <br /> 2005 <br /> ENVIRONMENT HEALTH <br /> PERMIT/SERVICES <br /> Mr. Chris Neudeck <br /> Kjeldsen, Sinnock, and Neudeck <br /> 711 N. Pershing Ave. <br /> Stockton, CA 95203 <br /> REVIEW OF LIMITED SOIL ASSESSMENT SIL VA TRUCKING YARD, 8355 S. MANTHEY <br /> ROAD, FRENCH CAMP, CALIFORNIA <br /> Central Valley Regional Water Quality Control Board staff(staff)has reviewedthe report Limited Soil <br /> Assessment Silva Trucking Yard submitted by Kleinfelder Inc. on 23 March 2005. The report discusses <br /> results of soil investigation at the Silva Trucking Yard on Manthey Road in Stockton. The Silva <br /> Trucking Yard is an approximately 115,000 square foot lot covered with 6 to 9 inches of gravel. <br /> Approximately 25 percent of the gravel is composed of waste tile from MonierLifetile. Previously, <br /> waste tile from MonierLifetile at a different site was classified designated waste due to soluble <br /> concentrations of TPH-diesel and hexavalent chromium. Staff has the following comments about the <br /> report: <br /> 1. Soluble TPH-diesel was detected in the sample of parent material (hand picked tile from the <br /> gravel) and in soil sample L2-0". TPH-diesel in the other 4 soil samples was non-detect. <br /> 2. All samples,background,parent material and 5-soil samples,were non-detect for hexavalent <br /> chromium. However, detection limits ranged from 50 to 500 ppb, and the water quality goal for <br /> hexavalent chromium is 21 ppb. Because of the high detection limits, staff is uncertain if <br /> chromium contamination occurs at this site or not. <br /> 3. In order to complete the site assessment all background,parent material and soil samples should <br /> be re-analyzed for hexavalent chromium. Additionally, a sample of storm water should be <br /> collected from the site and analyzed for TPH-diesel and hexavalent chromium. Results should <br /> be submitted as an addendum to the report to San Joaquin County Environmental Health <br /> Department and Central Valley Regional Quality Control Board. <br /> California Environmental Protection Agency <br /> Co Recycled Paper <br /> The energy challenge facing California is real. Every Califomian needs to take immediate action to reduce energy consumption. <br /> For a list of simple ways you can reduce demand and cut your energy costs,see our Web-site at http://www.swreb.ca.gov/rwqcb5 <br />