My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009291
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MILGEO
>
17230
>
2600 - Land Use Program
>
PA-1200141
>
SU0009291
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:55 AM
Creation date
9/6/2019 10:11:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0009291
PE
2632
FACILITY_NAME
PA-1200141
STREET_NUMBER
17230
Direction
E
STREET_NAME
MILGEO
STREET_TYPE
AVE
City
RIPON
APN
24529017 23
ENTERED_DATE
7/31/2012 12:00:00 AM
SITE_LOCATION
17230 E MILGEO AVE
RECEIVED_DATE
7/26/2012 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MILGEO\17230\PA-1200141\SU0009291\APPL.PDF \MIGRATIONS\M\MILGEO\17230\PA-1200141\SU0009291\CDD OK.PDF \MIGRATIONS\M\MILGEO\17230\PA-1200141\SU0009291\EH COND.PDF \MIGRATIONS\M\MILGEO\17230\PA-1200141\SU0009291\CORRESPOND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e. LIGHTING: Lighting shall be provided and comply with the following: <br /> (1) If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> (2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that such <br /> light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> f. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> (1) Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty(20)feet wide. (Development Title Section 9-1015.5) <br /> g. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title with the <br /> following modifications and be included on the Site Plan. All portions of any sign shall be set back a <br /> minimum of five (5) feet from any future right-of-way line, including any corner cut-off (snipe). <br /> (Development Title Section 9-1710.2[g]) <br /> h. BUILDING CODE REQUIREMENTS: The following California Building Code and San Joaquin <br /> County Ordinance requirements will be applicable and shall be incorporated in the construction plans <br /> before submittal to the Building Inspection Division: <br /> (1) The proposed occupancy will be F-1/S-1. <br /> (2) A grading plan shall be submitted and approved and a grading permit issued by the Building <br /> Inspection Division prior to performing any excavation or filling of earth material. <br /> (3) Provide parking for the physically disabled. The space(s) shall be located as close as possible <br /> to the primary entrance. (C.C.R., Title 24). <br /> (4) Provide identification signs for the parking space(s) including the "tow away, sign at each <br /> entrance or visible from each space(C.C.R., Title 24). <br /> (5) The slope of a parking space shall not exceed %inch per foot(C.C.R.,Title 24). <br /> (6) Provide one van parking space. <br /> (7) Provide restrooms conforming with all disabled access requirements (C.C.R., Title 24) Uniform <br /> Plumbing Code,Table 4-1. <br /> (8) Provide engineered plans for the addition, accessible restrooms, and parking. <br /> (9) A soils report is required. <br /> h. CALIFORNIA FIRE CODE: The following California Fire Code and San Joaquin County Ordinance <br /> Code requirements will be applicable and shall be incorporated in the construction plans before <br /> submittal to the Community Development Department for a building permit. <br /> (1) Fire flow and hydrants will be provided for the proposed project by the use of: Appendix B and C <br /> of the California Fire Code and NFPA 1142 of the National Fire Code. <br /> Conditions of Approval -3 - <br />